turck TBEN-LF Series Скачать руководство пользователя страница 1

 
 

 

TBEN-LF 

EtherNet/IP

TM

 Configuration 

Guide 

 
 
 
 
0719A 

Содержание TBEN-LF Series

Страница 1: ...TBEN LF EtherNet IPTM Configuration Guide 0719A...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...Restore IP Address 000 8 2 4 TURCK Service Tool TST 8 2 4 1 Search F5 9 2 4 2 DHCP Server F6 9 3 TBEN LF Quick View 12 3 1 Installation instruction and pinout 12 3 1 1 Dimensions and connector assign...

Страница 4: ...sign and a signal word that expresses the gravity of the danger The warnings have absolutely to be observed DANGER DANGER indicates an immediately dangerous situation with high risk the death or seve...

Страница 5: ...S files revision 2 7 The Rockwell PLC demo 1756 L72 controller v30 1756 EN2TR Ethernet Bridge Studio5000 Logic Designer V30 1 4 Feedback about these instructions We make every effort to ensure that th...

Страница 6: ...ault rotary switches are set at 000 with default IP address of IP address 136 129 1 1 Netmask 255 255 0 0 NOTE Position 000 is used to Restore or recover the default IP address if lost or forgotten 2...

Страница 7: ...sting an IP address assignment The setup procedure from any switch position Turn OFF device power and set switches to 300 or 400 Turn ON device power Start BOOTP DHCP server and assign IP address Wait...

Страница 8: ...a setup while restoring IP address From any switch position Set the address switches to 000 Cycle the power of the device and wait 10sec Set switches to either static position or 300 400 500 600 mode...

Страница 9: ...ARGEE and BEEP features by TURCK multiprotocol device DHCP server ARGEE status BEEP status Frequently used action buttons functions are Search F5 Change F2 DHCP F6 Action F4 2 4 1 Search F5 The Search...

Страница 10: ...ize DHCP server Highlight the device with 0 0 0 0 IP address Figure 2 7 Device DHCP client active view Click Change F2 A Change device configuration pop up page appears Assign IP address and click at...

Страница 11: ...11 Figure 2 8 Set IP Configuration Click at Stop DHCP F6 button Figure 2 9 Stop DHCP server...

Страница 12: ...the device installation guidance connector s assignment power distribution and grounding requirements are as follows 3 1 1 Dimensions and connector assignment Figure 3 1 Connector assignment 3 1 2 Eth...

Страница 13: ...te inputs Connect digital sensors to the device according to the pin assignment Figure 3 3 Discrete input wiring diagram Discrete outputs Connect digital actuators to the device according to the pin a...

Страница 14: ...cording to the pin assignment Figure 3 5 Discrete combined IO wiring diagram 3 1 4 Power connector pin assignment and distribution Connect power to the device according to the pin assignment Figure 3...

Страница 15: ...fic 10Mbps none off No Ethernet link Check Ethernet connection ERR green on No diagnostic message red on Diagnostic message pending BUS green on Active connection to a master blinking Device is ready...

Страница 16: ...XP LED Status I O LED Color Status Meaning Remedy LED 0 15 green on IO signal active input or output off IO signal off input or output red blinking Overcurrent at input Check input short condition Sol...

Страница 17: ...17 3 2 IO data maps TBEN LF 16DIP TBEN LF 16DOP TBEN LF 8DIP 8DOP TBEN LF 16DXP...

Страница 18: ...Input short at connector Cx x 0 1 7 OSC x Output short at condition at output x x 0 1 15 Device IO channels I x Input channel x 0 1 15 O x Output channel x 0 1 15 TBEN LG Configuration assembly data a...

Страница 19: ...Cs using ETHERNET MODULE Generic Ethernet Module profile TBEN LF configuration requirements Catalog Number Generic Ethernet Module Comm Format Data INT Select Connection Parameters listed for specific...

Страница 20: ...20 3 3 1 TBEN LF 16DIP Figure 13 TBEN LF 16DIP configuration page 3 3 2 TBEN LF 16DOP Figure 14 TBEN LF 16DOP configuration page...

Страница 21: ...21 3 3 3 TBEN LF 16DXP Figure 15 TBEN LF 16DXP configuration page 3 3 4 TBEN LF 8DIP 8DOP Figure 16 TBEN LF 8DIP 8DOP general page...

Страница 22: ...ects are defined hereafter Following VSC Object Classes Class Code Object type 100 0x64 Gateway Object 117 0x75 DXP Object Figure 4 2 Vendor Specific objects Common service Common class and instance s...

Страница 23: ...set 14 0x0E yes Get_Attribute_Single Figure 4 5 Identity Object Assembly Object Class code 04 0x04 Instance 103 0x67 Attributes Attribute Access Name Data type Value 3 03h Get Input data ARRAY of BYTE...

Страница 24: ...topology USINT 2 0x02 Get Network status USINT 10 0x0A Get Active supervisor address STRUCT 12 0x0C Get Capability flags DWORD Supported services Service code Class Instance Service 14 0x0E yes yes Ge...

Страница 25: ...ical Link Structure of Path Size UINT Path Padded EPATH 5 0x05 Get Interface Configuration Structure of Get IP address UDINT Get Network mask UDINT Get Gateway address UDINT Get Name server UDINT Get...

Страница 26: ...of USINT 4 0x04 Get Interface counters Structure of UDINT 5 0x05 Get Media counters Structure of UDINT 6 0x06 Set Interface control Structure of Control bits WORD Forced intf Speed UINT 7 0x07 Get In...

Страница 27: ...16 0x10 yes Set_Attribute_Single Figure 4 20 Gateway Object DXP Object Class code 117 0x75 Instance 1 attributes Attribute Access Name Data type Value 113 71h Get Digital In Out Input value DWORD 0 C...

Страница 28: ...Channel 0 1 Channel 1 2 Channel 2 3 Channel 3 4 Channel 4 5 Channel 5 6 Channel 6 7 Channel 7 8 Channel 8 9 Channel 9 10 Channel 10 11 Channel 11 12 Channel 12 13 Channel 13 14 Channel 14 15 Channel...

Страница 29: ...INT 0 255 156 9Ch Get Set Digital In Out 7 Pulse stretch USINT 0 255 157 9Dh Get Set Digital In Out 8 Pulse stretch USINT 0 255 158 9Eh Get Set Digital In Out 9 Pulse stretch USINT 0 255 159 9Fh Get S...

Страница 30: ...timer The timer stretches an input discrete single In 10msec increments The time base is 10msec Example 0 timer disabled default value 1 10 msec delay 10 100 msec delay ATTENTION DXP object attribute...

Страница 31: ...are located nationwide Including all major metropolitan marketing areas For Application Assistance or for the location of your nearest TURCK distributor call 1 800 544 7769 Specifications in this manu...