Technical Data
Technical data
RU40U…-M18…
RU130U…-M18…
RU130U…-M30…
Blind zone S
min
2.5 cm
15 cm
15 cm
Operating range
40 cm
130 cm
130 cm
Resolution
0.5 mm
1 mm
1 mm
Minimum size
– switching range
– measuring range
5 mm
50 mm
10 mm
100 mm
10 mm
100 mm
Operating voltage
15…30 VDC
15…30 VDC
15…30 VDC
Rated operational
current
≤ 150 mA
≤ 150 mA
≤ 150 mA
No-load current
≤ 50 mA
≤ 50 mA
≤ 50 mA
Operating
temperature
-25…+45 °C
-25…+45 °C
-25…+45 °C
Storage temperature
-40…+80 °C
-40…+80 °C
-40…+80 °C
Switching hysteresis
5 mm
10 mm
10 mm
Switching frequency
7Hz
8 Hz
8 Hz
Approvals
CE, cULus
CE, cULus
CE, cULus
Technical data
RU300U…-M30…
RU600U…-M30…
Blind zone S
min
30 cm
60 cm
Operating range
300 cm
600 cm
Resolution
1 mm
1 mm
Minimum size
– switching range
– measuring range
25 mm
250 mm
50 mm
500 mm
Operating voltage
15…30 VDC
15…30 VDC
Rated operational
current
≤ 150 mA
≤ 150 mA
No-load current
≤ 50 mA
≤ 50 mA
Operating
temperature
-25…+70 °C
-25…+50 °C
Storage temperature
-40…+80 °C
-40…+80 °C
Switching hysteresis
25 mm
≤ 50 mm
Switching frequency
4 Hz
1.6 Hz
Approvals
CE, cULus
CE, cULus
UL conditions: T
a
0…+85 °C, use the same power supply for all circuits.