13
V01.01 | 2016/10
4.4.1
Setting options
The devices have three setting options:
■
Setting via manual bridging (short-circuit)
■
Setting via connected teach adapter (accessories to be ordered separately)
■
Setting via buttons
4.4.2
Diffuse mode sensors
When using diffuse mode sensors, either a switching point or a switching window is defined.
The switching window is used for window or hysteresis functions.
Diffuse mode sensors with NC function
When diffuse mode sensors with NC function are used, a switching point is taught in for a
switching output. The output behaves as follows:
0
1
SP1
detection range
blind
zone
Fig. 4: Diffuse mode sensors with NC function — behavior of the switching output
Diffuse mode sensors with NO function
When diffuse mode sensors with NO function are used, a switching point is taught in for a
switching output. The output behaves as follows:
0
1
SP1
detection range
blind
zone
Fig. 5: Diffuse mode sensors with NO function — behavior of the switching output