Setting
RU200-CK40 – Setting via a teach adapter
24
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
9.1
RU200-CK40 – Setting via a teach adapter
Selecting the output
Select switching output 1: Press and hold down the pushbutton on the adapter to GND
for 2…7 s.
Select output 2: Press and hold down the pushbutton on the adapter to GND for 8…13 s.
Setting the switching point
Switching point
Out2
Out1
GND/T1 > 8 s
13 s
LED GN 2 × 1 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
Measure and save
Fail
LED GN/YE
1.5 s × 5 Hz
OK
LED GN
1.5 s × 5 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
Normal operation
U
B
/T2 > 2 s
LED YE
1 × 8Hz
Cancel
Fig. 38: Setting the switching point
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
Select the switching output.
Position the object for the switching point.
Store the switching point: Press and hold down the pushbutton on the adapter to GND
for 2…7 s.
a
The individual switching point has been taught in successfully if the green LED flashes for
1.5 s at a frequency of 5 Hz.