Inductive angle sensor
with analog output
Ri360P1-DSU35TC-ELi-Exi
Edition
•
2016-06-25T06:44:38+02:00
1 / 5
Hans Turck GmbH & Co.KG
ñ
D-45472 Mülheim an der Ruhr
ñ
Witzlebenstraße 7
ñ
Tel. 0208 4952-0
ñ
Fax 0208 4952-264
ñ
ñ
www.turck.com
Type code
Ri360P1-DSU35TC-ELi-Exi
Ident no.
1593015
Measuring principle
inductive
Resolution
12 bit
Measuring range
0…360°
Nominal distance
1 mm
Repeatability
ð
0.025 % of full scale
Linearity deviation
ð
0.3 % f.s.
Temperature drift
ð
± 0.02 % / K
Ambient temperature
-25…+70 °C
in the explosion hazardous area see instruction
leaflet
Operating voltage
14… 30VDC
at the connection point of the sensor
Residual ripple
ð
10 % U
ss
Rated insulation voltage
ð
0.5 kV
Short-circuit protection
yes
Wire breakage / Reverse polarity protection
yes/ complete
Output function
2-wire, Analog output
Current output
4…20mA
22 mA loop current during teach
Load resistance current output
ð
[(U
B
-14 V) / 20 mA] k
ò
Sample rate
500 Hz
Valve control
Exi (max. 30 V)
Approval acc. to
KEMA 03 ATEX 1122 X Issue no. 2
Internal capacitance (C
i
) / inductance (L
i
)
0 nF / 0 µH
Device designation
É
II 2 G Ex ia IIC T6 Gb / II 2 D Ex ia IIIC T85 °C
Db
(max. U
i
= 30 V, I
i
= 120 mA, P
i
= 600 mW)
Dimensions
71 x 60 x 35.4 mm
Housing material
Plastic, PP-GF30
Housing material, positioning element
plastic, PA66 + PA6I/6T-GF40
Connection
terminal chamber
Vibration resistance
55 Hz (1 mm)
Shock resistance (EN 60068-2-27)
30 g
Protection class
IP67
MTTF
138 years acc. to SN 29500 (Ed. 99) 40 °C
Included in delivery
Positioning element P1-Ri-DSU35, countersunk
screw M6 x 25, 2 cylinder screw M5 x 12, 2 lock
washers A5
■
ATEX category II 2 G, Ex Zone 1
■
ATEX category II 2 D, Ex Zone 21
■
Rectangular, housing DSU35
■
Plastic, PP-GF30-VO
■
Detection of angular range 0° to 360°
■
P1-Ri-QR14 positioning element includ-
ed in delivery
■
Measuring range programmable via
switch in the Terminal chamber
■
Immune to electromagnetic interference
■
Resolution, 12-bit
■
2
-
wire, 14…30 VDC
■
Analog output
■
4 … 20 mA
■
Terminal chamber
Wiring Diagram
Functional principle
Inductive measuring principle provides
more safety
Based on the functional principle of RLC cou-
pling, the sensor operates absolutely wear-
free and is immune to magnetized metal splin-
ters and other interference fields.
Owing to the differential analysis, the output
signal remains almost unchanged, even if the
position of the positioning element deviates
from the ideal axis of rotation.