background image

Inductive angle sensor

with analog output

Ri360P1-DSU35TC-ELi-Exi

Edition

 • 

2016-06-25T06:44:38+02:00

1 / 5

Hans Turck GmbH & Co.KG 

ñ

 D-45472 Mülheim an der Ruhr 

ñ

 Witzlebenstraße 7 

ñ

 Tel. 0208 4952-0 

ñ

 Fax 0208 4952-264 

ñ

 [email protected] 

ñ

 www.turck.com

Type code

Ri360P1-DSU35TC-ELi-Exi

Ident no.

1593015

Measuring principle

inductive

Resolution

12 bit

Measuring range

0…360°

Nominal distance

1 mm

Repeatability

ð

 0.025 % of full scale

Linearity deviation

ð

 0.3 % f.s.

Temperature drift

ð

 ± 0.02 % / K

Ambient temperature

-25…+70 °C
in the explosion hazardous area see instruction
leaflet

Operating voltage

14… 30VDC
at the connection point of the sensor

Residual ripple

ð

 10 % U

ss

Rated insulation voltage

ð

 0.5 kV

Short-circuit protection

yes

Wire breakage / Reverse polarity protection

yes/ complete

Output function

2-wire, Analog output

Current output

4…20mA
22 mA loop current during teach

Load resistance current output

ð

 [(U

B

 -14 V) / 20 mA] k

ò

Sample rate

500 Hz

Valve control

Exi (max. 30 V)

Approval acc. to

KEMA 03 ATEX 1122 X Issue no. 2

Internal capacitance (C

i

) / inductance (L

i

)

0 nF / 0 µH

Device designation

É

 II 2 G Ex ia IIC T6 Gb / II 2 D Ex ia IIIC T85 °C

Db
(max. U

i

 = 30 V, I

i

 = 120 mA, P

i

 = 600 mW)

Dimensions

71 x 60 x 35.4 mm

Housing material

Plastic, PP-GF30

Housing material, positioning element

plastic,  PA66 + PA6I/6T-GF40

Connection

terminal chamber

Vibration resistance

55 Hz (1 mm)

Shock resistance (EN 60068-2-27)

30 g

Protection class

IP67

MTTF

138 years acc. to SN 29500 (Ed. 99) 40 °C

Included in delivery

Positioning element P1-Ri-DSU35, countersunk
screw M6 x 25, 2 cylinder screw M5 x 12, 2 lock
washers A5

ATEX category II 2 G, Ex Zone 1

ATEX category II 2 D, Ex Zone 21

Rectangular, housing DSU35

Plastic, PP-GF30-VO

Detection of angular range 0° to 360°

P1-Ri-QR14 positioning element includ-

ed in delivery

Measuring range programmable via

switch in the Terminal chamber

Immune to electromagnetic interference

Resolution, 12-bit

2

-

wire, 14…30 VDC

Analog output

4 … 20 mA

Terminal chamber

Wiring Diagram

Functional principle
Inductive measuring principle provides

more safety

Based on the functional principle of RLC cou-
pling, the sensor operates absolutely wear-
free and is immune to magnetized metal splin-
ters and other interference fields.
Owing to the differential analysis, the output
signal remains almost unchanged, even if the
position of the positioning element deviates
from the ideal axis of rotation.