Area: Scanning – Parameters
The following parameters can be set in the Scan area to detect data:
Default values are shown in
bold
type.
Parameter
Selection
Description
Mode
Once
Each detected tag is indicated with an audible signal. The
Once
mode is
suitable, for example, for Inventory commands if several tags are inside
the detection range.
Geiger
In
Geiger
mode, the handheld outputs a signal each time a tag is detec-
ted. In Geiger mode, the handheld outputs a permanently audible signal
each time a tag is read, even if only one tag is in the detection range. The
tag list graphically indicates how often a tag was already read. The
Geiger
mode is suitable for tasks such as searching for tags.
Power
0…
100
%
Changes the transmission output.
USER memory
–
Opens the user interface for setting the number of bytes to be read from
the USER memory. The data is read without an offset. If the set number of
bytes cannot be read, the tag is not reported.
TID memory
–
Opens the user interface for setting the number of bytes to be read from
the TID memory. The data is read without an offset. If the set number of
bytes cannot be read, the tag is not reported.
Location
Yes
The location of each tag read is recorded. The location depends on GPS,
WiFi and mobile wireless stations (if available).
No
The location of the read tags is not recorded.
Max. scans/second
–
Opens the user interface for setting the max. number of Inventory re-
quests per second. Restricting the Inventory requests increases battery
life.
Seconds to restart
–
Opens the user interface for setting the time after which a data record is
to be sent.
Maximum number of tags –
Opens the user interface for setting the max. number of tags after which
an Inventory operation is ended.
8.3.3
Area: Display – Parameters
The following parameters for displaying the data can be set in the Display area.
Default values are shown in
bold
type.
Parameters
Selection
Description
EPC/UID display
Default:
Hexa-
decimal
Format for the display of UID and EPC
USER memory
Hexa-
decimal
Display of the data from the USER memory in hexadecimal format
TEXT (ASCII)
Display of the data from the USER memory in ASCII format
8.3.4
Area: Security – Parameters
The
Security
area enables a password to be specified for the configuration of the Scan com-