Setting
30
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Explanation
Options
Function
GEOM
Container shape
CYLV
Vertical cylinder
CYLH
Horizontal cylinder
COnE
Conical container
SPHR
Spherical container
CUST
Customized
MOFF
Sensor position
Mounting offset of the sensor (threaded end to
container bottom)
Default: Detection range
EMTY
Lowest level
(DPCT, LVL, LPCT, VOL, VPCT)
Measured from container bottom
(MOFF - EMTY ≤ s_max.)
Default: 0
FuLL
Highest level
(DPCT, LVL, LPCT, VOL, VPCT)
Measured from container bottom
(MOFF - FuLL ≥ s_min, FuLL - EMTY > a_min)
Default: Measuring range minus blind zone
DIA
Container diameter
(CYLV, CYLH, SPHR)
Diameter of cylindrical and spherical containers;
DIA must be ≥ FuLL for CYLH and SPHR.
Default: 564.1895 mm
LnGt
Container length
(CYLV, CYLH)
Total length of cylindrical containers; with CYLV LnGt
must be ≥ FuLL.
Default: Measuring range minus blind zone
BOT
Type of container bottom
(CYLV, CYLH)
FLAT
Flat bottom
DISH
Two dish-shaped (convex bottoms at both ends)
DBot
Diameter at the bottom edge of
cone (COnE)
Lower diameter of conical containers
Default: 0.0
hBot
Bottom edge of cone (COnE)
Position and height of bottom diameter of conical
containers (= length of cylindrical section at the
bottom)
Default: 0.0
DToP
Diameter of the upper edge of
the cone (COnE)
Upper diameter of the conical containers
Default: 0.0
hToP
Upper edge of cone (COnE)
Position or height of the upper diameter of conical
containers (hToP > hBot)
Default: 0.0
9.3
Setting via IO-Link
The device can be parameterized within the technical specifications (see data sheet) via the
IO-Link communication interface – both offline, e.g. with the configuration tool as well as also
online via the controller. An overview of the different functions and properties that can be set
and used for IO-Link or SIO mode can be found in the chapter “Setting” and in the IO-Link para-
meter manual of the device. Detailed instructions on the parameterization of devices via th
e IO-Link interface are provided in the IO-Link commissioning manual.
All the parameters can be changed in IO-Link mode via the controller during commissioning as
well as during operation. In SIO mode the device operates according to the last setting made in
IO-Link mode.