25
[email protected] • www.turck.com • 2015/02
EC Conformity/Approvals
Technical Data
RU40…-M18…
RU130…-M18…
RU130…-M30…
RU300…-M30…
Storage temperature
-40…+80 °C
Weight
51 g
51 g
105 g
105 g
Switching hysteresis
5 mm
10 mm
10 mm
25 mm
Switching frequency
7Hz
8 Hz
8 Hz
4 Hz
Response time
75 ms
65 ms
65 ms
125 ms
Readiness delay
≤ 300 ms
Approvals
CE, cULus
15.1
Factory settings
Setting
RU40…-M18…
RU130…-M18…
RU130…-M30…
RU300…-M30…
Output behavior
Switching output 2
NO contact
NO contact
NO contact
NO contact
Output behavior
Switching output 4
4…20 mA
4…20 mA
4…20 mA
4…20 mA
Analog range
Teach-in range =
Sensing range
Teach-in range =
Sensing range
Teach-in range =
Sensing range
Teach-in range =
Sensing range
Switch point
40 cm (end of sens-
ing range)
130 cm (end of sens-
ing range)
130 cm (end of sens-
ing range)
300 cm (end of sens-
ing range)
Operating mode
Normal operation
Normal operation
Normal operation
Normal operation
For the factory settings of the IO-Link parameters see the IO-Link parameter overview in the document “IO-Link
parameters for “High End” ultrasonic sensors” (D102012).
16
EC Conformity/Approvals
16.1
Conformity with EC directives
The product is subject to the following EC directive:
■
2004/108/EC (EMC Directive)
Conformity with this directive is achieved by observing the following harmonized standard:
■
EN 60947-5-2:2007 (Low Voltage Switchgear and Controlgear, Part 5-2: Control circuit devices and switch ele-
ments – proximity switches)
The EC declaration of conformity is available for download from the TURCK product database.
16.2
Approvals: cULus
Further requirements for mounting in UL installations:
■
Use the same voltage for all circuits.
■
Install the ultrasonic sensors with UL-listed connection cables (approved for 30 V and 0.15 A min.) in the electri-
cal installation of the plant.
Ultr
asonic sensors
“H
igh End“