V01.01 | 2022/03
19
9.2
Setting via FDT/IODD
The devices can be set via a PC with an FDT frame application (e.g. PACTware). All the required
Turck software components can be downloaded via the Turck Software Manager:
n
PACTware
n
IODD
n
DTM for USB-2-IOL-002 IO-Link adapter
n
IODD DTM Configurator
The Turck Software Manager can be downloaded free of charge from
The USB-2-IOL-002 USB IO-Link adapter (ID 6825482) is required for connecting to the PC.
A 4-pin standard sensor cable (e.g. RKC4.4T-2- RSC4.4T/TXL; ID 6625608) is required for
connecting the sensor to the USB-2-IOL-002 IO IOL-Link adapter.
Further information on setting the devices via IODD with a configuration tool is provided in the
IO-Link commissioning manual.
9.3
Setting and visualization with the Turck Vibration Monitor
The device can be configured and tested via a Turck IO-Link master (e.g. TBEN-S2-4IOL). The
integrated web server of the IO-Link master offers access to all the parameters of the sensor
IODD. An overview of the IO-Link parameters as well as descriptions are provided in the IO-Link
parameter manual. The Turck Vibration Monitor is also available for visualizing process data.
Access to the sensor parameters and the Turck Vibration Monitor requires the connection of a
Turck IO-Link master. The following table shows the firmware version of the IO-Link masters
required for using the Turck Vibration Monitor:
IO-Link master
Firmware version
FEN20-4IOL
V1.2.0.0
TBEN-L4-8IOL
V3.3.2.0
TBEN-L5-8IOL
V3.3.2.0
TBEN-LL-8IOL
V1.1.1.0
TBEN-S2-4IOL
V3.4.1.0
Refer to the instructions for use of the relevant device for information on the Turck IO-Link
masters.
Connect the IO-Link master to the power supply.
Connect the IO-Link master to a PC via the Ethernet interface.
Connect the CMVT… to an IO-Link port of the IO-Link master.
If no IO-Link master is available with the appropriate firmware version, the CMVT… can be set
via the web demo and configuration tool. This requires the use of an IO-Link adapter (e.g.
USB-2-IOL-0002; ID 6825482) for the connection between the PC and the sensor. The above-
mentioned FEN20-4IOL and TBEN… IO-Link masters can also be used with older firmware ver-
sions. The web demo and configuration tool enable access to the sensor via the local web
browser.
The web demo and configuration tool can be downloaded free of charge from
Содержание CMVT Series
Страница 1: ...Your Global Automation Partner Instructions for Use CMVT Condition Monitoring Sensors with IO Link...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Страница 21: ...V01 01 2022 03 21 Load the device specific IODD into the web server via Load IODD Fig 10 Loading the IODD...
Страница 29: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100031992 2022 03 100031992...