3.8
Reset to factory settings
Besides the hardware rest using the rotary coding switches (see
F_Reset (Reset to factory setting)
), the TURCK IP Address Tool as well as the web server (see
) offer the possibility to reset the devices to the factory settings.
3.8.1
IP Address Tool
NOTE
Resetting the device to factory settings
via rotary coding/DIP switches
deletes the CODE-
SYS-program in the device, see also
F_Reset (Reset to factory setting) (page 23)
Resetting the device to factory settings
via DCP-based
services (via Turck IP Address Tool
or TIA-Portal/Step7) does not delete the CODESYS-program (see also
.
r
Fig. 18: IP Address Tool, reset to factory settings