background image

Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

1|3

BI1.5-HS865-Y1

Inductive sensor 

Technical data

Type

BI1.5-HS865-Y1

ID number

1004201

Rated switching distance

1.5 mm

Mounting conditions

Flush

Secured operating distance

≤ (0,81 x Sn)  mm

Correction factors

St37 = 1; Al = 0.3; stainless steel = 0.7; Ms =

0.4

Repeat accuracy

≤ 2 % of full scale

Temperature drift

≤ ± 10 %

Hysteresis

1…10 %

Ambient temperature

-25…+70 °C

Output function

2-wire, NAMUR

Switching frequency

5 kHz

Voltage

Nom. 8.2 VDC

Non-actuated current consumption

≥ 2.1 mA

Actuated current consumption

≤ 1.2 mA

Approval acc. to

KEMA 02 ATEX 1090X

Internal capacitance (C

i

)/inductance (L

i

)

150 nF/150 µH

Device marking

É

 II 2 G Ex ia IIC T6 Gb / II 1 D Ex ia IIIC T95

°C Da

(max. U

i

 = 20 V, I

i

 = 60 mA, P

i

 = 130 mW)

Design

Smooth barrel, 6.5 mm

Dimensions

32 mm

Housing material

Metal, CuZn, Chrome-plated

Active area material

Plastic, PA12-GF30

End cap

Plastic, PP

Electrical connection

Cable

Cable quality

Ø 4 mm, Blue, Lif9YYW, PVC, 2 m

Features

ATEX category II 2 G, Ex zone 1

ATEX category II 1 D, Ex zone 20

SIL2 (Low Demand Mode) acc. to IEC 61508, PL

c acc. to ISO 13849-1 at HFT0

SIL3 (All Demand Mode) acc. to IEC 61508, PL e

acc. to ISO 13849-1 with redundant configura-

tion HFT1

Smooth barrel, Ø 6.5 mm

Active face, lateral

Chrome-plated brass

DC 2-wire, nom. 8.2 VDC

Output acc. to DIN EN 60947-5-6 (NAMUR)

Cable connection

Wiring diagram

Inductive sensors detect metal objects

contactless and wear-free. For this, they use a

high-frequency electromagnetic AC field that

interacts with the target. Inductive sensors

generate this field via an RLC circuit with a ferrite

coil.

Отзывы: