V02.00 | 2021/05
7
3
For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still
exist. Observe the following warnings and safety notices to prevent damage to persons and
property. Turck accepts no liability for damage caused by failure to observe these warning and
safety notices.
3.1
Intended use
These devices are designed solely for use in industrial areas.
The readers with an integrated RFID interface are used for contactless data exchange with the
BL ident tags in the Turck UHF RFID system. The following table shows the operating frequency
of the devices:
Type code
Operating frequency
Application range
TN-UHF-…-AUS-LNX
920…926 MHz
Australia, New Zealand
TN-UHF-…-BRA-LNX
915…928 MHz
Brazil
TN-UHF-…-CHN-LNX
920.5…924.5 MHz
China
TN-UHF-…-EU-LNX
865…868 MHz
Europe, Turkey, India
TN-UHF-…-JPN-LNX
916.7…920.9 MHz
Japan
TN-UHF-…-KOR-LNX
917…920.8 MHz
Korea
TN-UHF-…-MYS-LNX
919…923 MHz
Malaysia
TN-UHF-…-NA-LNX
902…928 MHz
North America
(USA, Canada, Mexico)
TN-UHF-…-RUS-LNX
866…868 MHz
Russia
TN-UHF-…-SGP-LNX
920…925 MHz
Singapore
These devices may only be started up under the following conditions:
n
The particular frequency range is permissible for the use of UHF-RFID.
n
The operating frequency range of the devices is compliant with the permissible UHF RFID
range of the region.
n
A valid certification and/or approval is available for the region of use.
The integrated RFID interface enables the readers to communicate directly via TCP/IP with
higher-level systems such as ERP systems. Read data is sent to the higher-level system via the
device.
Four configurable digital channels are also provided for connecting digital sensors and actuat-
ors.
The devices may only be used as described in these instructions. Any other use is not in accord-
ance with the intended use. Turck accepts no liability for any resulting damage.
Содержание 100000897
Страница 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Reader...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Страница 19: ...V02 00 2021 05 19 Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan...
Страница 69: ...V02 00 2021 05 69 fclose fh else printf failed on writing n return 1...
Страница 75: ...V02 00 2021 05 75 else printf failed on writing n return 1 return EXIT_SUCCESS...
Страница 91: ...V02 00 2021 05 91 Restart the device to complete the update Click Reboot Fig 65 Restarting the device...
Страница 93: ...V02 00 2021 05 93 Select RS485 RFID and confirm with OK Fig 67 Selecting the RS485 interface...
Страница 97: ...V02 00 2021 05 97 Click the Select BL File button Fig 73 Button selecting a BL file...
Страница 106: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003067 2021 05 100003067...