Turbo E2T Series Скачать руководство пользователя страница 1

 

 

 

 

 

ECONOMISER 

SERIES

 

E2T

 

USER MANUAL

 

 

 

 
 
 
 
 
 
 
 
 
 
 
01/03/2016 
Manual Release 1.25 
Hardware Release 1.3

 

TURBO

 s.r.l.

 

Electronic Control Systems For Dust Collectors 

e-mail: [email protected]  

web: www.turbocontrols.eu 

Tel. ++39 (0)362 574024   Fax ++39 (0)362 574092

 

Содержание E2T Series

Страница 1: ...2T USER MANUAL 01 03 2016 Manual Release 1 25 Hardware Release 1 3 TURBO s r l Electronic Control Systems For Dust Collectors e mail info turbocontrols it web www turbocontrols eu Tel 39 0 362 574024...

Страница 2: ...ctable ranges for any application Pressure measurements expressed in kPa Power voltage 115 230 Vac 50 60 Hz selectable by means of jumpers optional 24 Vac Vdc Output voltage 24 Vdc 24 115 230 Vac sele...

Страница 3: ...cted to the unit are normally closed The activation of a solenoid valves causes them to open and consequently let out a jet of air Alarm Relay The two alarm relays contain 2 clean contacts on terminal...

Страница 4: ...oned in a place easily accessible Before working on the equipment to perform any operation switch off the magneto thermic differential switch For electric operations always remove voltage wait 30 seco...

Страница 5: ...correct use of the device may cause damage to the device or to the devices connected to it Furthermore incorrect use or tampering with the device may cause injury Waterproofness of the casing is guara...

Страница 6: ...ect and then and increase or decrease the values The OK button is used to confirm data and reset alarms If the button is pressed during ordinary operation the activity hour meter is displayed The Butt...

Страница 7: ...ble values d24 a24 115 230 Default a24 F06 Manual output activation Possible values 1 number of outputs set in F04 Press SET to activate the set output F07 Zero dP threshold Possible values 0 00 kPa 3...

Страница 8: ...es 0 disabled 1 enabled Default 0 disabled F19 dP threshold for precoating function Possible values 0 00 kPa 3 99 kPa step 0 01 Default 2 00 kPa F20 Enabling Minimum dP Alarm function if detected for...

Страница 9: ...of range detected To use 230V valves switch the device off and move the output voltage selection jumper to 230V If the jumper is in the correct position press OK then SET select the F05 function with...

Страница 10: ...o dP value alternating with 0 if the enabling contact 14 15 is closed and the fan is off o dP value only if the fan is enabled and active In manual mode F01 0 o OFF if the enabling contact is open 14...

Страница 11: ...F12 The pulse time of the valves will always be that defined in F02 while the pause time in this case is defined in F14 The display alternately shows the number of the valve activated and the word PCC...

Страница 12: ...11 Connection Diagram Pressure Sensor dP Pressure inlet dirty section dP Depression inlet clean section...

Страница 13: ...he relay is activated Alarm Relay K2 6 7 terminals The relay is normally closed opens in case of alarm and opens to the control unit off in the absence of power The alarm that open the relays is Max d...

Страница 14: ...13 Fuse Table Voltage Value 230 Vac 1 A 115 Vac 1 A 24 Vdc Vac 3 A Jumper Configuration Power Input 115 VAC 230 VAC Jumper Configuration Output 115 VAC 230 VAC 24 VAC 24 VDC...

Страница 15: ...14 Installation Casing Dimensions 4 8 Outputs Weight 1 8 Kg...

Страница 16: ...15 Installation Casing Dimensions 12 16 Outputs Weight 2 1 Kg...

Страница 17: ...threshold 0 kPa F08 Cycle start dP threshold 0 80 kPa F09 Cycle stop dP threshold 0 40 kPa F10 Max dP level 3 00 kPa F11 Fan mode 0 from contact 1 from dP 1 F12 Fan dP threshold if F11 1 If fan off 0...

Страница 18: ...rranty Exclusions The warranty will be cancelled in case of Signs of unauthorised tampering and repairs Incorrect use of the device not respecting technical data Incorrect electric connections Failure...

Страница 19: ...er to MANUAL mode F01 0 Do alarm messages appear Check the alarm code with the table Do the alarms fail to activate signalling devices System wiring errors No power to alarm devices The alarm devices...

Страница 20: ...Options All Complies with the following directives Directive 2014 30 EU Electromagnetic Compatibility compliant with Harmonised European standards EN61000 6 2 2005 class B of EN61000 6 4 2001 Directiv...