background image

Turbo Air Speeds up the Pace of Innovation

Food Prep Tables

Sandwich/Salad Units

Installation and Operation Manual

Please read this manual completely before attempting to install or operate this equipment

TST-28SD

TST-36SD

TST-48SD

TST-60SD

TST-72SD

www.turboairinc.com

Full Stainless Steel Visible Exterior

Содержание TST-28SD

Страница 1: ...ables Sandwich Salad Units Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment TST 28SD TST 36SD TST 48SD TST 60SD TST 72SD www...

Страница 2: ...R 134A 9 9A 372lbs TST 60SD 1 2 115V 60Hz R 134A 8 9A 316lbs The serial number is located on the rating label which is on the left interior wall Please retain the unit s serial number for service purp...

Страница 3: ...crew the caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters ROTATION CAST...

Страница 4: ...the water away And then set the drain pan back up as below drawing please Model TST 28SD TST 28SD 12 TUR 28SD 2 When the drain pan install on the compressor mounted base lift up the vaporizing pipe a...

Страница 5: ...5 HOW TO CLEAN THE PAN SUPPORTER 1 Remove the Guide Pans and Pans Then pull out the Pan Supporter Clean the pan supporter and reinstall in place...

Страница 6: ...strong enough to support the total weight of the cabinet and contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cool...

Страница 7: ...RE STARTING If disconnected wait 5 minutes before re starting Before cleaning turn unit off at power switch 1 CLEANING THE INTERIOR AND EXTERIOR The interior and exterior of the unit can be cleaned us...

Страница 8: ...ool for higher temperature and Cold for lower temperature 4 The thermostat controls compressor s on off by sensing inside temperature REFRIGERATORS COLD OFF NORMAL COOL TUR 28SD TUF 28SD COLD OFF NORM...

Страница 9: ...ly The backside of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy seasons The door is opened too frequently or left open...

Страница 10: ...ter Household and industrial cleaners are the worst type of chlorides to use 8 step that can help prevent rust on stainless steel 1 Using the correct cleaning tools Use non abrasive tools when cleanin...

Страница 11: ...er to wipe standing cleaning agents and water as soon as possible Allow the stainless steel equipment to air dry Oxygen helps maintain the passivity film on stainless steel 7 Hydrochloric acid muriati...

Страница 12: ...fter shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or...

Страница 13: ...se accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED...

Страница 14: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...