TROUBLESHOOTING
The following points are not malfunctions:
• A water-flowing sound can be heard when the compressor stops.
This is the sound of REFRIGERANT flowing.
• The compressor does not run during the defrost cycle.
Note:
Formation of condensation on and around the edge of the door and the front side
of the cabinet is normal. Gurgling noises inside the refrigerating circuit are normal.
SYMPTOMS
CAUSES
SOLUTIONS
Cooler is freezing
food.
• Thermostat set too cold.
• Turn the thermostat
setting to a higher
temperature position.
The unit does not
refrigerate at all.
• There is a power connection
failure problem.
• Check the power cord
and plug in correctly.
The unit does not
refrigerate well.
• The unit is in sunlight or near a
heating device.
• The unit contains hot food or
too much food.
• The unit door is opened too
frequently or left open long.
• The temp. dial is not on the
correct position.
• The condenser is clogged.
• Check the installation
place.
• Check the condition of
stored food.
• Check the position of
the temp control dial.
There is a loud
noise.
• The floor is too weak or the
leveling feet is set incorrectly.
• The back-side of the unit is too
close to the wall.
• Check the installation.
There are dew-
drops on the unit
exterior.
• High-moisture air can produce
dewdrops during rainy season.
• Wipe with a dry cloth.
There are dew-
drops on the unit
interior.
• The door is opened too
frequently or left open long.
• Damp food is stored.
• Keep the door closed
to remove dewdrops.
The door does
not close tightly.
• The door is bent.
• The unit is a levelling failure.
• The door gasket has come out.
• Level the unit again.
• Reposition the gasket.