Turbo Air TGIM-23W-N Скачать руководство пользователя страница 1

SIGN PANEL

DOOR ASSEMBLY

SIGN PANEL

DOOR ASSEMBLY

BACK SPACER

SHELF(U)

SHELF(F)

BOTTOM GRILLE

COMPRESSOR

CONDENSER COIL

DOOR

HANDLE

EVAPORATOR FAN

MOTOR BLADE

EVAPORATOR
FAN MOTOR

EVAPORATOR
COIL

CONDENSER
FAN MOTOR

FRONT VIEW

FRONT VIEW

SIDE VIEW

Model No. :

TGIM-23*
TGIM-49*

GLASS DOOR ICE MERCHANDISERS

Please read this manual completely before attempting to install or operate this equipment!

An asterisk(*) in a model number means the external finish of cabinet, black & white color, 
and each model is identical except the aesthetic difference which doesn't affect the performance.

Содержание TGIM-23W-N

Страница 1: ...TOR COIL CONDENSER FAN MOTOR FRONT VIEW FRONT VIEW SIDE VIEW Model No TGIM 23 TGIM 49 GLASS DOOR ICE MERCHANDISERS Please read this manual completely before attempting to install or operate this equipment An asterisk in a model number means the external finish of cabinet black white color and each model is identical except the aesthetic difference which doesn t affect the performance ...

Страница 2: ...ICATIONS SERIAL NUMBER CONTENTS The serial number can be found on the data label located inside the unit Please retain this serial number for service purposes GLASS DOOR ICE MERCHANDISERS TGIM 23 1 3 6 5A 820W defrosting input 110 120 V 60Hz R 134a 376lbs TGIM 49 2 3 11 8A 1160W defrosting input 110 120 V 60Hz R 404A 587lbs MODEL COMP H P Amp watt V Hz REFRIGERANT CRATED WEIGHT ...

Страница 3: ...oid hot corners and locations near stoves High ambient temperature will significantly reduce cooling efficiency 4 INDOOR USAGE ONLY This unit is designed and tested for indoor use only Outdoor usage will void its warranty 5 STABILIZATION Turn leg levelers counter clockwise as necessary in order to properly level cooler 6 LEVELING Please make sure that the unit levels from the front to the back and...

Страница 4: ...t be free of dust dirt and grease This will require periodic cleaning condenser fins should be cleaned at least every three months 90 days or as needed 3 CLEAN THE GASKET The door gasket should be cleaned frequently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Please make sure that the power cord is connect...

Страница 5: ...omatically cycled by the electronic controller PCB F Sensor 4 The defrost cycle is automatically controlled by the D sensor and the PCB 5 Push the temperature up button for higher temperatures and the temperature down button for lower temperatures 6 Evaporator fan motor will run after all doors are completely closed 7 Good air flow in freezer is critical Be careful when stationing the product so t...

Страница 6: ...REEZE Turbo air LAMP POWER T F FAN DOOR INTERIOR TEMP INDICATOR SEE PAGE 9 TEMP CONTROL BUTTON SEE PAGE 8 LAMP SWITCH POWER SWITCH SEE PAGE 8 TURBO FREEZE BUTTON DOOR OPENING TURBO FREEZE FAN RUNNING DISPLAY PANEL OF FREEZER TGIM 23 ...

Страница 7: ...EEZE LAMP ON OFF ON OFF POWER TEMPERATURE INTERIOR TEMP INDICATOR SEE PAGE 9 TEMP CONTROL BUTTON SEE PAGE 8 LAMP SWITCH POWER SWITCH SEE PAGE 8 TURBO FREEZE BUTTON DOOR OPENING TURBO FREEZE FAN RUNNING DISPLAY PANEL OF FREEZER TGIM 49 ...

Страница 8: ...tronic controller PCB features an intellectual algorithm which can recognize the defrost period that eliminates any icing on the evaporator which automatically adjusts to optimal energy saving temperatures For additional options this feature can be monitored and adjusted remotely by a wireless connection 2 If it is necessary to change the intervals of defrost due to unusual operating conditions it...

Страница 9: ...turned on 2 Evaporator fan motor will stop when the door is opened INNER TEMPERATURE DISPLAY FAN RUNNING INDICATOR 1 If the door is opened an indicator will be turned on 2 30 seconds after the door opened it will sound beep three 3 times 3 1 minute after it is opened it will sound beep again five 5 times 4 After 5 minutes of staying open the beeping sound will ring continuously 5 Once the door is ...

Страница 10: ...ay is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open long Damp food is stored The door is bent The unit is a levelling failure The door gasket has come out SYMPTOMS CAUSES SOLUTIONS Push the temperature button to the suitable position Check the power cord and plug in it correctly Check the installation place Che...

Страница 11: ...ystem contains R404A or R134a refrigerant and polyol ester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtain...

Страница 12: ...NIT installed in my place of business Installation date The above warranties are in effect from this installation date or 90 days after shipment from TURBO AIR whichever comes first MANUFACTURING COMPANY TURBO AIR MANUFACTURING COMPANY 4184 Conant St Long Beach CA 90808 U S A WARRANTY REGISTRATION CARD MANUFACTURING COMPANY MAIL CARD IMMEDIATELY This card must be mailed immediately after installat...

Страница 13: ...4184 CONANT ST LONG BEACH CA 90808 U S A Canada Toll Free 800 627 0032 For Service 800 381 7770 TEL 310 900 1000 FAX 310 900 1077 http www turboairinc com ...

Отзывы: