Turbo Air Super Deluxe TSF-23SD Скачать руководство пользователя страница 1

Turbo Air Speeds up the Pace of Innovation

Full Stainless Steel Interior and Exterior

www.turboairinc.com

SOLID DOOR

REFRIGERATORS

TSR-23SD*

TSR-35SD

TSR-49SD

TSR-72SD

SOLID DOOR

FREEZERS

TSF-23SD

TSF-35SD

TSF-49SD

TSF-72SD

Super Deluxe Series

Refrigerators & Freezers

Installation and Operation Manual

Please read this manual completely before attempting to install or operate this equipment

Содержание Super Deluxe TSF-23SD

Страница 1: ...airinc com SOLID DOOR REFRIGERATORS TSR 23SD TSR 35SD TSR 49SD TSR 72SD SOLID DOOR FREEZERS TSF 23SD TSF 35SD TSF 49SD TSF 72SD Super Deluxe Series Refrigerators Freezers Installation and Operation Ma...

Страница 2: ...15V 60Hz R 134A 9 0A 357lbs TSR 49SD 1 3 115V 60Hz R 134A 9 2A 427lbs TSR 72SD 1 2 115V 60Hz R 134A 11 3A 602lbs MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT TSF 23SD 1 2 115V 60Hz R 404A 7 8A 293lbs T...

Страница 3: ...contents 3 DO NOT PLAVE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this u...

Страница 4: ...ed 3 CLEAN THE GASKET The door gasket should be cleaned frequently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER C...

Страница 5: ...default temprature setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB D Senser 4 The Defrost cycle is automatically controlled by the R sensor and the PCB 5 Set...

Страница 6: ...GERATOR 9 TEMPERATURE T C 8 7 6 5 4 3 2 1 FAN DOOR TURBO COOLING TEMPERATURE F TEMP SETTING TURBO COOLING FAN RUNNING DOOR OPENING TURBO COOLING BUTTON TEMP CONTROL BUTTON SEE TO PAGE 7 INNER TEMP SEE...

Страница 7: ...de the compressor will return to the normal operation 3 During the Turbo Cooling mode works the temperature Up Down button will not affect the compressor s operation 1 By pushing the up down button yo...

Страница 8: ...will be turned on 2 Evaporator fan motor is activated when the door both doors for TSR 49SD all three doors for TSR 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 I...

Страница 9: ...ller PCB F Senser 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Set level toward 1 for higher temperature and toward 9 for lower temperatures 6 The interior light is ac...

Страница 10: ...ER 9 TEMPERATURE D F 8 7 6 5 4 3 2 1 FAN DOOR MANUAL DEFROST TEMPERATURE F TEMP SETTING MANUAL DEFROST FAN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP CONTROL BUTTON SEE TO PAGE 11 INNER TEMP SEE...

Страница 11: ...lighted higher level numbers 1 The electronic defrost controller is set at the factory to provide a defrost cycle every 6 hours 4 times per a day 2 If it is necessary to change the intervals of defros...

Страница 12: ...be turned on 2 Evaporator fan motor is activated when the door both doors for TSF 49SD all three doors for TSF 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 In cas...

Страница 13: ...he back side of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open long...

Страница 14: ...fter shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or...

Страница 15: ...se accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED...

Страница 16: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...