background image

 

 

t: 01977 661234  
e: [email protected]  
w: www.tunstall.com 
Version: IL1117 

 

 

Motion Sensor 869 (61005/35) 

Installation Guide 

 

 

 

Содержание 61005/35

Страница 1: ...t 01977 661234 e enquiries tunstall co uk w www tunstall com Version IL1117 Motion Sensor 869 61005 35 Installation Guide...

Страница 2: ...l 5 3 Assigning the Motion Sensor 869 to the Tunstall Home Unit 8 4 Modes of Use 9 Walk Test Mode 9 Auto Low Battery ALB and Auto Presence AP Mode Overview 10 Auto Low Battery ALB and Auto Presence AP...

Страница 3: ...avoid detecting a user who may be on the floor following a fall fall zone feature This means that in the event of a fall any small movements from the person who has fallen on the floor are not picked...

Страница 4: ...a period of time when used in conjunction with a Lifeline home unit or other Tunstall Telecare enabled systems Motion Sensor 869 Illustration Motion Sensor 1 Front Cover 2 Battery Note positive termi...

Страница 5: ...by any furniture in the room as shown in Fig 2 Depending upon the construction of the wall the sensor can be fitted using either hook and loop pads or screws and wall plugs For the latter method take...

Страница 6: ...way from Direct sunlight Fans or air conditioning units Vapour or high humidity which may cause condensation Curtains blinds or screens Fluorescent lights Unstable locations prone to vibrations or sho...

Страница 7: ...7 Fig 2 Fall Zone Positioning...

Страница 8: ...hold the function button on the Motion Sensor until a solid red LED is displayed Continue to press the function button for approximately three seconds until the red LED turns off and then release the...

Страница 9: ...est mode which will be active for three minutes The timer will not be reset if the sensor detects movement during this time 4 Ask the user to walk in front of the sensor The detection beam should be p...

Страница 10: ...ssage will be raised to the monitoring centre if the Tunstall unit has not seen eighteen consecutive AP messages AP failure alarms will be continually generated if sensors are removed from the propert...

Страница 11: ...ent battery and dispose of according to local regulations 3 Wait for twenty seconds before inserting a new 3 6V AA Lithium battery checking that the polarity is correct 4 Tunstall recommends using the...

Страница 12: ...nvironmental Group Group 2 Indoor in general EMC EN 55032 EN 301 489 1 EN 301 489 3 Radio EN300 220 3 1 Safety EN60950 1 Design Manufacture Installation and Service ISO 9001 2015 Declaration of Confor...