USER MANUAL
DIGITECH ECO
1500/2000 VA
UNINTERRUPTIBLE POWER SUPPLY
UPS
Страница 1: ...USER MANUAL DIGITECH ECO 1500 2000 VA UNINTERRUPTIBLE POWER SUPPLY UPS ...
Страница 2: ...N Front Panel Back Panel 6 7 1 On Off Button 6 AC Mode Green Lighting 7 Battery Mode Orange Flashing 8 Fault Red Lighting 2 AC Input 3 Output Receptacles 4 USB Communication Port 5 Fax Modem Protection 8 5 3 4 2 1 ...
Страница 3: ...ay have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase Compact size light weight Microprocessor control guarantees high reliability Equipped with Boost and Buck AVR Green Power Function for energy saving DC Start Function Cold Start Provides AC Overload protection This UPS is specially designed for Personal Computers with multi functions...
Страница 4: ...h of the power receptacles supplied on the back of the UPS 5 Turn On Off To turn on the UPS unit press the power lightly To turn off the UPS unit press the power switch again 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environ me...
Страница 5: ...or to cleaning and do not use liquid or spray detergent Do not dispose of batteries in a fire as they may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes lt may be toxic Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The...
Страница 6: ... or improper operation to battery Power cord is loose 1 Remove some non critical load 2 Charge battery 8 hours or more 3 Replace with the same type of battery Reconnect the power cord properly Overload of the UPS 1 Charge battery up to 8 hours 2 Replace with the same type of battery 3 Press the power switch again Verify that the load matches the UPS capability specified in the specs No LED display...
Страница 7: ...UTPUT BATTERY CAPACITY 10 Voltage range 2 6 ms 10 ms max Transfer time Simulated sine wave 4 6 hours recover to 90 capacity Waveform 392 x 177 x 211 2 x 12V 9Ah Dimensions D x W x H mm 10 7 392 x 177 x 211 11 45 Net weight kg Type Number Charging time 0 40 C 0 90 non condensing Humidity 40 dB Noise level 220 230 240 VAC Voltage 162 265 VAC Voltage range 1500 VA 900 W 2000 VA 1200 W ...