Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
121
0x6072 Max motor torque
‰TN
1~10000
3000
Immediately
Parameter description:
For details, please refer to parameter
User permission:
User/Engineer.
Parameter permission:
Read and Write
Figure 7.7-6.
Diagram of torque command limit
Rotor Compensation Angle and Phase Sequence Detection Setting
7.7.8
Number
Index
Name
Unit
Setting range
Default value
Effective
time
95
0x20D1
Rotor
Compensation
Angle Detection
Setting
—
0x00000000~0x1F1F0F01
0x0A190100
Restart
Parameter Description:
Byte0: Detection method selection
0x00 - Conventional detection method;
0x01 - Static detection method
Byte1: Phase sequence detection sensitivity of static detection method
0x01 - 0.1 ºC;
0x02 - 0.2 ºC;
0x03 - 0.3 ºC;
0x04 - 0.4 ºC;
0x05 - 0.5 ºC;