Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Chapter 1
Safety Information
Electrical Safety
1.1
The servo drive is an industrial electronic product, please keeps away from the device during operation, and
do not perform live wiring, or personal injury may be caused. Extreme caution should be taken when handling or
approaching drives. If the drive has a fault or alarm, please determine the detailed fault or alarm content with the
debugging software, and then solve it accordingly. For detailed faults and alarms, please refer to relevant chapters
in the user manual.
Safety Guidance
1.2
Only trained and experienced engineers should perform system design, installation, commissioning and
maintenance. Please read the safety information and the instruction manual carefully prior to operation.
Neither stopping the servo drive nor its safety function can ensure the input and output voltages are isolated,
which can cause bodily injury, therefore, please disconnect the power supply with a qualified electrical insulation
device before wiring.
In any case, hazard analysis must be conducted upon drive failure, and further steps must be taken to reduce
the risk if necessary, for example, the overspeed protection device should be applied upon speed control failure,
and the fault protection mechanical braking device should be applied upon motor braking failure.
Environmental Requirements
1.3
The transport, storage, installation and use of the drive must follow the instructions described in these manual
as well as specific environmental requirements.
Operational Guidance
1.4
Personnel responsible for design, installation and commissioning should follow all relevant regulations, such
as national wiring rules, accident prevention regulations, electromagnetic compatibility (EMC) regulations and so
on. The selection of cable, fuse and other protection devices should be in accordance with the relevant design
specifications, and the equipment must be reliably grounded.
Motor Safety
1.5
Make sure the installation and maintenance of the motor are according to the instructions of the motor
manufacturer.
If the driven motor exceeds the maximum output of the drive, please contact our technical support.
Low-speed operation of the motor may lead to overheating, and the motor must be equipped with a
thermistor, and if necessary, forced cooling fan is also required.
The motor parameters in the drive can affect the normal operation of the motor, and the default value
does not apply to all motors.
Do not touch a motor that has been running for a long time, which may result in burns.
Parameters Adjustment
1.6
Some parameters have a significant impact on the drive operation. Before changing such parameters, please
consider its possible effect on the control system carefully, do not change parameters blindly.
1
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...