TSI Instruments BlueSky 8143 Скачать руководство пользователя страница 1

 

www.tsi.com 

BlueSky

 

Air Quality Monitor 

Model 8143 

 
 
 
Operation and Maintenance Manual 

 
 
 
 
 

P/N 6013929 Rev. G 
August 2022 

 
 

 

 

Содержание BlueSky 8143

Страница 1: ...www tsi com BlueSky Air Quality Monitor Model 8143 Operation and Maintenance Manual P N 6013929 Rev G August 2022...

Страница 2: ...es product enhancements and new products By registering your instrument TSI will be able to send this important information to you http register tsi com As part of the registration process you will be...

Страница 3: ...inal manufacturer s warranty applies e This warranty does not cover calibration requirements and seller warrants only that the instrument or product is properly calibrated at the time of its manufactu...

Страница 4: ...are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limited warranty of Seller This LIMITATION OF WARRANTY AND LIABILITY may not be amended...

Страница 5: ...11 Chapter 3 Operation 15 Overview 15 Registering your BlueSky Monitor s and Account Onboarding 15 Viewing Data from one or more BlueSky Monitors 19 Downloading Data from one or more BlueSky Monitors...

Страница 6: ...nual Warning WARNING Warning means that unsafe use of the instrument could result in serious injury to you or cause damage to the instrument Follow the procedures prescribed Caution and Warning Symbol...

Страница 7: ...install the BlueSky monitor less than 1 2 meters or 4 feet from the ground TSI recommends 3 meters or 10 feet Setting the bottom of BlueSky monitor too close to a surface will result is water splashin...

Страница 8: ...itor is designed to be used outdoors in highly polluted areas where particulate concentrations can be as high 1000 g m3 NOTICE Installation videos can be found on our website tsi com Using the search...

Страница 9: ...d When operated according to the manufacturer s instruction this device is a Class 1 laser product as defined by U S Department of Health and Human Services standards under the Radiation Control for H...

Страница 10: ...ycling As part of TSI Incorporated s effort to have a minimal negative impact on the communities in which its products are manufactured and used If instrument becomes obsolete return to TSI for disass...

Страница 11: ...ser The BlueSky monitor connects to the internet using wireless technology Wi Fi There is no need to install an app on your smartphone Logged data is also stored on the internal mircoSD card The BlueS...

Страница 12: ...Item Part Number Qty Description 8143 1 BlueSky Air Quality Monitor N A 1 Mounting Bracket N A 1 Screw N A 1 IP68 Rated 5V Power Supply N A 2 Zip Tie BlueSky Monitor Replacement Parts Listed below are...

Страница 13: ...ens 814301 Replacement Power Supply NA Plug Type A NEMA 1 15 814302 Replacement Power Supply EU Plug Type C CEE 7 16 814303 Replacement Power Supply UK Plug Type G BS 1363 814309 Replacement Power Sup...

Страница 14: ...modem EU version CE certified modem w indoor rated power supply 8145 SO Solar system includes 1 12VDC 8 A Hr battery 1 charge controller 1 panel 1 outdoor enclosure and mounting hardware 8145 CS Sola...

Страница 15: ...ents from the shipping package A quick start guide is shipped with each instrument It provides the necessary steps to configure the Wi Fi settings for connecting the device to a local Wi Fi network an...

Страница 16: ...to the cloud Data older than a week will be available only on the SD card Currently customers cannot read the SD card data and upload it to the cloud NOTICE The SD card is user accessible by removing...

Страница 17: ...The monitor is now like a Hotspot to which a Wi Fi device such as your laptop or mobile device can connect to This will allow you to configure the devices Wi Fi settings 3 Using a laptop tablet or a s...

Страница 18: ...and click Connect You will be prompted to enter a password network security key NOTICE Your computer or phone may indicate that there is no internet connection present This is common because the Blue...

Страница 19: ...P address 192 168 4 1 as shown Click Enter on the keyboard 8 The browser will prompt you to enter the SSID network name and password of the network you want the BlueSky monitor to connect to This netw...

Страница 20: ...ork and start transmitting data to the cloud 11 Finally move the Wi Fi switch back into the operate position so it can connect to the local Wi Fi network The BlueSky monitor will start uploading data...

Страница 21: ...ternet connection NOTICE The monitor does not have the capability to connect to public Wi Fi networks that requires a second step of browser authentication such as a free public hotel or airport netwo...

Страница 22: ...ng disconnected during operation Mounting options are shown below a Pole mount WARNING DO NOT install the BlueSky monitor too close to the ground Minimum distance from ground should be 1 2 meters or 4...

Страница 23: ...ripod The thread on the bottom of the device should fit most camera tripods 4 Plug the other end of the power supply into a weatherproof in use resistant IP 68 rated outdoor receptacle enclosure an ex...

Страница 24: ...must follow local electrical codes WARNING DO NOT install the BlueSky monitor upside down The bottom of the device is designed to allow for aerosol to enter the PM sensor The bottom of the instrument...

Страница 25: ...LED at the bottom is flashing once every 2 seconds If not go to the troubleshooting section to fix connectivity issues 2 From any location open your web browser and enter the BlueSky Outdoor Air Qual...

Страница 26: ...by entering in the required information and click DONE If you do not see the Device Registration screen click the Activate New Device icon on bottom right corner of the map Click on Use Browser Locat...

Страница 27: ...device pin location if needed and or click Done 9 If you would like to use the Data Services and API functionality of tsilink com click on API Enter the device s that you want to register to this TSI...

Страница 28: ...keep the box uncheck Click DONE when completed 11 If you have trouble creating an account or need additional information please go to https tsi com resources tsi link monitoring and research faqs tsi...

Страница 29: ...your BlueSky device pin is located 3 Click on the device pin 4 Click on the history button 5 Click on the three dots in the top left corner and select Export CSV Downloading Data from the microSD Car...

Страница 30: ...cated on the top left corner as shown below 5 Remove the card and insert the card into a PC to download the data 6 Once you have downloaded the data reinsert the card into the BlueSky monitor If the B...

Страница 31: ...Device Status definitions Column A Date in Universal Time Coordinated GMT Column B PM1 0 Mass concentration data in g m3 Column C PM2 5 Mass concentration data in g m3 Column D PM4 Mass concentration...

Страница 32: ...entration data in g m3 Column C Applied PM2 5 Custom Calibration Setting Multiplication Factor Column D PM10 Mass concentration data in g m3 Column E Applied PM10 Custom Calibration Setting Multiplica...

Страница 33: ...water to leak into the device which may damage the electronics inside 3 Make sure the mounting bracket is rigidly mounted to the mounting pole wall or tripod Tighten screws if necessary 4 Check to mak...

Страница 34: ...or and the PC board from the PC board 4 To remove the sensor from the base push on the black plastic release to the right of the carrier board and pull up on one side of the carrier board until it is...

Страница 35: ...e Action Monitor does not turn on Bad Power Connection or Failed Power Supply Check all power connections including the power port on the bottom of the device and where the power supply is plugged int...

Страница 36: ...found on the serial number label of each monitor Additionally the following firewall ports need to be available a DNS 53 UDP b SNTP 123 UDP c HTTPS 443 TCP d MQTT 8883 TCP 3 blinks every second follo...

Страница 37: ...o the monitor The monitor is located near an object that obstructs the flow Move the BlueSky monitor into a more open area and ensure the bottom of the device is open to free air Readings are not corr...

Страница 38: ...28 Chapter 5 This page intentionally left blank...

Страница 39: ...at 0 5 m Accuracy 10 100 1000 g m3 when compared to a DustTrak DRX monitor Zero Stability 1 g m3 Sample Flow Rate 0 3 L min Response Time 1 second Start up Time 8 seconds Operating Temperature Range...

Страница 40: ...er Requirements AC DC Power Supply 100 to 240 VAC 50 60 Hz INPUT 5 VDC OUTPUT Device Input Power 5 VDC Power Consumption 5 W Environmental Installation Requirements Maximum Altitude 3000 meters 10 000...

Страница 41: ...ing from the sensor Therefore use best judgement to determine if there is an actual sensor failure If the device seems to be reporting data accurately when compared to other BlueSky devices and or a r...

Страница 42: ...of cloud connection No action required PM Sensor Status 0 No Errors N A 1 Sensor not factory calibrated Replace PM sensor All PM sensors from TSI should be factory calibrated 2 Sensor cleaning occurre...

Страница 43: ...ensor limit 256 Sensor fan error No action required If problem persists consider replacing PM sensor N O T I C E It is also possible that more than one error may occur during the logging interval If t...

Страница 44: ...more information USA Tel 1 800 680 1220 UK Tel 44 149 4 459200 France Tel 33 1 41 19 21 99 Germany Tel 49 241 523030 India Tel 91 80 67877200 China Tel 86 10 8219 7688 Singapore Tel 65 6595 6388 P N 6...