Limitation of Warranty and Liability 

Seller warrants the goods sold hereunder, under normal 
use and service as described in the operator's manual, shall 
be free from defects in workmanship and material for 
twenty-four (24) months, or the length of time specified in 
the operator's manual, from the date of shipment to the 
customer. This warranty period is inclusive of any 
statutory warranty.  This limited warranty is subject to the 
following exclusions: 

a.  Hot-wire or hot-film sensors used with research 

anemometers, and certain other components when 
indicated in specifications, are warranted for 90 days 
from the date of shipment. 

b.  Parts repaired or replaced as a result of repair services 

are warranted to be free from defects in workmanship 
and material, under normal use, for 90 days from the 
date of shipment. 

c.  Seller does not provide any warranty on finished 

goods manufactured by others or on any fuses, 
batteries or other consumable materials. Only the 
original manufacturer's warranty applies. 

d.  Unless specifically authorized in a separate writing by 

Seller, Seller makes no warranty with respect to, and 
shall have no liability in connection with, goods which 
are incorporated into other products or equipment, or 
which are modified by any person other than Seller.  

The foregoing is IN LIEU OF all other warranties and is 
subject to the LIMITATIONS stated herein. 

NO OTHER 

EXPRESS OR IMPLIED WARRANTY OF FITNESS 
FOR PARTICULAR PURPOSE OR 
MERCHANTABILITY IS MADE

TO THE EXTENT PERMITTED BY LAW, THE 
EXCLUSIVE REMEDY OF THE USER OR BUYER, 
AND THE LIMIT OF SELLER'S LIABILITY FOR ANY 
AND ALL LOSSES, INJURIES, OR DAMAGES 
CONCERNING THE GOODS (INCLUDING CLAIMS 
BASED ON CONTRACT, NEGLIGENCE, TORT, 
STRICT LIABILITY OR OTHERWISE) SHALL BE 
THE RETURN OF GOODS TO SELLER AND THE 
REFUND OF THE PURCHASE PRICE, OR, AT THE 
OPTION OF SELLER, THE REPAIR OR 
REPLACEMENT OF THE GOODS. IN NO EVENT 
SHALL SELLER BE LIABLE FOR ANY SPECIAL, 
CONSEQUENTIAL OR INCIDENTAL DAMAGES. 
SELLER SHALL NOT BE RESPONSIBLE FOR 
INSTALLATION, DISMANTLING OR 
REINSTALLATION COSTS OR CHARGES. No Action, 
regardless of form, may be brought against Seller more 
than 12 months after a cause of action has accrued.  The 
goods returned under warranty to Seller's factory shall be 
at Buyer's risk of loss, and will be returned, if at all, at 
Seller's risk of loss. 

Buyer and all users are deemed to have accepted this 
LIMITATION OF WARRANTY AND LIABILITY, 
which contains the complete and exclusive limited 
warranty of Seller. This LIMITATION OF WARRANTY 
AND LIABILITY may not be amended, modified or its 
terms waived, except by writing signed by an Officer of 
Seller. 

 

Service Policy 

Knowing that inoperative or defective instruments are as 
detrimental to TSI as they are to our customers, our service 
policy is designed to give prompt attention to any 
problems. If any malfunction is discovered, please contact 
your nearest sales office or representative, or call 
Customer Service at (800) 424-7427 (USA) and (1) 651-
490-2811 (International). 

Содержание ALNOR MicroManometer AXD 550

Страница 1: ...AXD 550 MicroManometer OWNER S MANUAL...

Страница 2: ...IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE TO THE EXTENT PERMITTED BY LAW THE EXCLUSIVE REMEDY OF THE USER OR BUYER AND THE LIMIT OF SELLER S LIABILITY FOR ANY AND A...

Страница 3: ...items to select any of the following press 7 Using the AXD 550 8 Basic Functions 8 To Change Units 8 To Hold a Reading For storage or printing 9 Measurement Modes 9 Pressure Selection 9 Velocity Selec...

Страница 4: ...ication Through Windows 95 16 Appendix D Pressure to Velocity Conversion Charts 16 Appendix E Correction Factors for Non Standard Conditions 17 Method 1 17 Method 2 17 Method 3 17 AXD 550 Density Corr...

Страница 5: ...can hold 100 readings of pressure velocity or volume For convenience memory can be organized into sections called pages All data is saved by the instrument s own battery powered system Readings can al...

Страница 6: ...unit off after a twenty minute period of keyboard inactivity To disable this feature follow the instructions in the menu selections section of this manual Attach hoses to the pressure ports at the top...

Страница 7: ...ions the AXD 550 will read small pressure changes Clearing the Memory If this is the first time you are using the AXD 550 clear the memory before using the instrument Clearing the memory is done with...

Страница 8: ...he RUN mode If the instrument is in any other mode pressing this key will exit that function and go back to the RUN mode without making any changes VOL The VOL key prepares the AXD 550 for air volume...

Страница 9: ...es and menu items After each entry appears on the display as the AXD 550 stores new information Menu Selections Pressing the MENU key activates the main menu Use the and keys to scroll through the ava...

Страница 10: ...he key scroll to or Press the key Press the ON OFF key to return to the RUN mode Note the serial port must be when interfacing to a computer Keep the port when not in use to conserve batteries tc allo...

Страница 11: ...rsion charts Volume Selection or reviewing the latest area Air volume measurement is achieved by multiplying a velocity reading by an area When you press the VOL key the menu appears on the display an...

Страница 12: ...ld the ON OFF key until appears then press the ON OFF key to return to the RUN mode To erase stored data Press the CLR key until appears Push the or key until appears Press to clear the memory Note Ke...

Страница 13: ...computer Make sure the serial port on the meter is enabled Review the stored date There must be data stored for printing If any of these problems persist call TSI for assistance Maintenance Periodic m...

Страница 14: ...s able to calculate averages automatically thus eliminating the need for additional calculations Refer to AVE on page 6 of this manual Traversing a Round Duct Using the log Tchebycheff method the duct...

Страница 15: ...ing the log Tchebycheff method Number of points or traverse lines per side Position relative to inner wall 5 0 074 0 288 0 500 0 712 0 926 8 0 061 0 235 0 437 0 563 0 765 0 939 10 0 053 0 203 0 366 0...

Страница 16: ...ll be used In any circumstance if the new value is more than 50 different than the old value 100 of the new value will be used This override percentage allows the meter to quickly attain a new value w...

Страница 17: ...l type in GEE1 then press the ENTER key Notice keep typing the G until it reappears on the terminal screen then continue typing EE1 Second method At the terminal and after following the steps under To...

Страница 18: ...eeds To Incoming Line Ends and Wrap Lines That Exceed Terminal Width click OK Click OK again to exit Properties Hyperterminal is now ready to receive information from the meter Save terminal configura...

Страница 19: ...te pressure temperature and relative humidity record the differential pressure from the AXD 550 the absolute pressure the temperature and the relative humidity at the measurement location Compute the...

Страница 20: ...1 29 1 32 1 35 250 1 15 1 18 1 20 1 22 1 25 1 27 1 29 1 31 1 34 1 36 1 40 300 1 20 1 22 1 24 1 27 1 29 1 31 1 34 1 36 1 39 1 41 1 44 350 1 24 1 27 1 29 1 31 1 34 1 36 1 39 1 40 1 43 1 46 1 49 400 1 27...

Страница 21: ...cy approximates the resolution e g differential pressure of 01 inches H2O accuracy statement is 01 x 01 01 or 0101 inches H2O or reading error is 101 of reading As differential pressure increases the...

Страница 22: ..._______________________________________________________________ Where Purchased _________________________________________________________________________ Describe Malfunction _________________________...

Страница 23: ...urrounded by at least 2 inches 5 cm of suitable shock absorbing material Include a purchase order that clearly shows the instrument model number and serial number a contact name phone fax number and R...

Страница 24: ...___________________________________________________________________________________ _______________________________________________________________________________________ ____________________________...

Страница 25: ...gh 4 digit 7 segment LCD no backlight 15 inch high 2 1 2 digit memory indicator Data Memory One hundred memory locations are available to store units of measure and pressure velocity or volume reading...

Страница 26: ...Cardigan Road Shoreview MN 55126 USA Toll Free 800 424 7427 Telephone 651 490 2811 September 2002 Fax 651 490 3824 Printed in USA www alnor com Part No 116 159 128 Rev 13 customerservice alnor com Co...

Отзывы: