Fig. 43889
2. Mark "ON/OFF" with a checkmark to activate the backstop
resistor.
3. Activate "Normal-active" with a checkmark.
The backstop resistor is active while the backgauge
approaches its position.
The function corresponds to "When stopping" if the backstop
resistor is set for a single program
resistor for single bending operations", pg. 4
.
or
Ø
Activate "Withdrawal active" with a checkmark.
The backstop resistor is active while the backgauge with-
draws from the workpiece.
The function corresponds to "When moving" if the back-
stop resistor is set for a single program
backstop resistor for single bending operations", pg.
4
).
4. Enter the strength of the backstop resistor between 0 and
100 %:
−
"Left": actuation of the left backstop resistor.
−
"Right": actuation of the right backstop resistor.
5. Deselect "ON/OFF" and then reselect it in order to apply the
change to the strength of the backstop resistor.
B579EN
2015-06-01
Operating the BendMaster
4
‐
37