8

Choosing a location

Install the control panel in a place that is protected from mois-
ture and wetness. 

So that it is easy to read the characters, install the con-
trol panel at eye height. 

•  Making the installation opening.

3±1

73

+1

84

+1

3.5

3.5

3.5

3.5

Fig. 19

 – Dimensions in mm. Picture not to scale

Electrical connection

Observe ESD regulations.

Lay the connector cable of the TIN Bus and the 
12 V   supply voltage in loops with no tension. The con-

trol panel must project approx. 20 cm out of the installation 
opening – with no tensile loading for the connector. Never pull 
the connector cable when it is connected to the control panel

•  Lay the connector cable (TIN Bus) to the heater or air condi-

tioning system and plug into the control panel.

•  Connect the 12 V connector cable and connect to the un-

switched 12 V   operating voltage (permanent positive). 
The heater and control panel Truma CP plus VarioHeat must 
be connected to the same circuit. 

•  The positive cable must be protected with a 1 A fuse.

TIN-Bus

CI-BUS

1

+ -

12 V

+ = red 
- = red/black

Fig. 20

 – View from the rear

1

  Only with variant Truma CP plus VarioHeat CI-BUS. By default, an 

external control panel (master) is connected.

Installation

•  Fix the frame to the wall with 4 screws. 

+

-

Ø max. 3.4 mm

Fig. 21

 – View from the front

•  Hook the control panel upper part into the frame with 

2 catches.

•  Fix the control panel upper part with a screw. 

•  Slide the rotary push button on to the shaft.

Fig. 22

– Installing the control panel upper part and rotary 

push button

 Electrical connections – heater

Lay the connector cables so that they cannot chafe. Also use 
edge protection or leadthrough bushing on sharp edges, such 
as holes on metal walls. The connector cables must not be 
fixed to or touch metallic equipment surfaces, the exhaust 
duct or the warm air ducts.

The electrical connection is made via an external cable 
harness. 

Take care with the connector cables so that they are not 
pulled out or squashed.

Содержание VarioHeat eco AU

Страница 1: ...Installation instructions Page 2 Truma VarioHeat eco AU...

Страница 2: ...c window switch optional 4 Exhaust duct 5 Warm air 6 Circulating air 7 Gas inlet connection with gas pressure test point 8 Type plate 9 VarioHeat pre pressure regulator Installation variants 30 max 10...

Страница 3: ...ing regulations AS NZS 5601 2 LP Gas installations in caravans and boats for non propulsive purposes LP Gas installations and any other statutory regulations Use with liquefied petroleum gas LP Gas in...

Страница 4: ...Install the heater in the directions shown Fig 2 Fig 7 on page 2 The functions of parts of the vehicle that are important for operation must not be adversely affected Clearance from combustible materi...

Страница 5: ...he mounting brackets to the housing of the heater in the respective hole pattern Fix the heater with the mounting brackets and the supplied bolts B 5 5 x 25 mm The heater must be screwed to the floor...

Страница 6: ...liance Slide the clamp 7 over the pipes Compress the exhaust duct 1 at the start so that coil sits on coil Slide the clamp 4 over the exhaust duct 1 Slide the exhaust duct 1 over the O ring 2a on to t...

Страница 7: ...cate an error Choosing a location When choosing a location remember that the room tempera ture sensor must not be exposed to direct heat radiation For optimum room temperature control we recommend tha...

Страница 8: ...control panel Truma CP plus VarioHeat must be connected to the same circuit The positive cable must be protected with a 1 A fuse TIN Bus CI BUS1 12 V red red black Fig 20 View from the rear 1 Only wi...

Страница 9: ...the supply line may have to be considered Connect the negative cable to the central earthing system If parts are connected directly to the battery the positive and negative cables must be fused No oth...

Страница 10: ...UNF 3 Fig 25 After installation you must check gas supply line for leaks in accordance with the pressure drop method Do not use matches candles or other sources of ignition when checking for gas leak...

Страница 11: ......

Страница 12: ...e relevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 1800 21 21 2...

Отзывы: