Fig.9

If the cowl is being installed directly underneath a win-
dow that will be opened, installation of an electric win-

dow switch (part no. 34030-34700) is recommended.

Refer to AS/NZS 5601.2 – LP Gas installations, for loca-
tion requirements of the flue terminal.

Visibility of the type plate

•  The scope of delivery includes a second type plate (dupli-

cate) with removable bar code.

 

– If the type plate on the heater is not visible after installa-

tion, the second type plate (duplicate) must be affixed to 
the heater in a clearly visible location.

 

– The duplicate must only be used in conjunction with the 

original.

Fastening the heater

Check whether the RV has a load-bearing floor or an access 
or intermediate floor to fix the heater – if this is unsuitable – 
create a load-bearing surface (e.g. glue a sheet of plywood on 
to the floor).

To fix the heater, use only the supplied mounting brackets 
(Fig. 11 – A, B, C, D), which must be fixed in the respective 
hole pattern 

Mounting bracket / hole pattern arrangement

Hole pattern

Mounting 
bracket

 

e

c

d

 

e

c

d

Not 

permitted

*

*

Not 

permitted

Not 

permitted

Not 

permitted

Not 

permitted

*  only in combination with 2 additional 

mounting brackets 

B

D

A

C

B

D

Installation examples

Vertical installation

Horizontal installation

 Fig. 10

•  Use only the supplied PT bolts (torque 1.5 Nm) to fix the 

mounting brackets to the housing of the heater (in the 
respective hole pattern). 

•  Fix the heater with the mounting brackets and the supplied 

bolts B 5.5 x 25 mm.

The heater must be screwed to the floor of the RV 
or the false floor in order to prevent the gas sys-

tem from becoming damaged because of movement 
while driving!

Exhaust duct

With the VarioHeat you must use Truma accessories (e. g. the 
Truma “Warm air basic kit” with 

•  wall cowl kit,EW 24
•  exhaust duct AA 24 (1m) and 
•  combustion air supply duct ZR 24 (1 m)

for the installation, as the heater has only been tested and ap-
proved with these ducts.

If the exhaust duct is beneath the floor, the vehicle floor 
must be leakproof. In addition, at least three sides beneath 

the vehicle floor must be free to ensure that the exhaust gas 
can be extracted without any obstruction (spoilers, snow, etc.).

Permissible duct lengths

Duct lengths from 30 cm to maximal 100 cm are 
permitted.

Refer to installation variants, Fig 2 – Fig. 6 (page 2).

• 

Do not

 crush or kink these ducts during installation.

Installing the wall cowl

•  Select a suitable location for the wall cowl. Refer to „Loca-

tion of the wall cowl“ page 4.

•  Drill a Ø 70 mm hole (8) (fill cavities near the cowl hole with 

wood). 

•  Seal with the supplied rubber seal (10). In case of structured 

surfaces, use plastic automotive sealant – not silicone.

•  Slide the rubber seal (10 – 

smooth side facing the wall)

 

and the clamp (4) on to the wall cowl inner part (11). 

•  Before you push the exhaust double duct through the hole, 

slide the clamp (7) over the pipes.

Содержание VarioHeat eco AU

Страница 1: ...Installation instructions Page 2 Truma VarioHeat eco AU...

Страница 2: ...c window switch optional 4 Exhaust duct 5 Warm air 6 Circulating air 7 Gas inlet connection with gas pressure test point 8 Type plate 9 VarioHeat pre pressure regulator Installation variants 30 max 10...

Страница 3: ...ing regulations AS NZS 5601 2 LP Gas installations in caravans and boats for non propulsive purposes LP Gas installations and any other statutory regulations Use with liquefied petroleum gas LP Gas in...

Страница 4: ...Install the heater in the directions shown Fig 2 Fig 7 on page 2 The functions of parts of the vehicle that are important for operation must not be adversely affected Clearance from combustible materi...

Страница 5: ...he mounting brackets to the housing of the heater in the respective hole pattern Fix the heater with the mounting brackets and the supplied bolts B 5 5 x 25 mm The heater must be screwed to the floor...

Страница 6: ...liance Slide the clamp 7 over the pipes Compress the exhaust duct 1 at the start so that coil sits on coil Slide the clamp 4 over the exhaust duct 1 Slide the exhaust duct 1 over the O ring 2a on to t...

Страница 7: ...cate an error Choosing a location When choosing a location remember that the room tempera ture sensor must not be exposed to direct heat radiation For optimum room temperature control we recommend tha...

Страница 8: ...control panel Truma CP plus VarioHeat must be connected to the same circuit The positive cable must be protected with a 1 A fuse TIN Bus CI BUS1 12 V red red black Fig 20 View from the rear 1 Only wi...

Страница 9: ...the supply line may have to be considered Connect the negative cable to the central earthing system If parts are connected directly to the battery the positive and negative cables must be fused No oth...

Страница 10: ...UNF 3 Fig 25 After installation you must check gas supply line for leaks in accordance with the pressure drop method Do not use matches candles or other sources of ignition when checking for gas leak...

Страница 11: ......

Страница 12: ...e relevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 1800 21 21 2...

Отзывы: