Fig. 1

Installation example

1  Room temperature sensor
2 Control panel 

Truma CP plus VarioHeat

3  Electric window switch (optional)
4 Exhaust duct
5 Warm air
6 Circulating air
7  Gas inlet connection 

with gas pressure test point

8 Type plate
9 VarioHeat pre-pressure regulator

Installation variants

30 - max. 100 cm

Fig. 2

30 - max. 100 cm

Fig. 3

 30 - 100 cm

max. 

30 cm

Fig. 4

30 - max. 100 cm

30 - max. 100 cm

Fig. 5

 

30 - 100 cm

max. 

30 cm

Fig. 6

Fig. 7

Содержание VarioHeat eco AU

Страница 1: ...Installation instructions Page 2 Truma VarioHeat eco AU...

Страница 2: ...c window switch optional 4 Exhaust duct 5 Warm air 6 Circulating air 7 Gas inlet connection with gas pressure test point 8 Type plate 9 VarioHeat pre pressure regulator Installation variants 30 max 10...

Страница 3: ...ing regulations AS NZS 5601 2 LP Gas installations in caravans and boats for non propulsive purposes LP Gas installations and any other statutory regulations Use with liquefied petroleum gas LP Gas in...

Страница 4: ...Install the heater in the directions shown Fig 2 Fig 7 on page 2 The functions of parts of the vehicle that are important for operation must not be adversely affected Clearance from combustible materi...

Страница 5: ...he mounting brackets to the housing of the heater in the respective hole pattern Fix the heater with the mounting brackets and the supplied bolts B 5 5 x 25 mm The heater must be screwed to the floor...

Страница 6: ...liance Slide the clamp 7 over the pipes Compress the exhaust duct 1 at the start so that coil sits on coil Slide the clamp 4 over the exhaust duct 1 Slide the exhaust duct 1 over the O ring 2a on to t...

Страница 7: ...cate an error Choosing a location When choosing a location remember that the room tempera ture sensor must not be exposed to direct heat radiation For optimum room temperature control we recommend tha...

Страница 8: ...control panel Truma CP plus VarioHeat must be connected to the same circuit The positive cable must be protected with a 1 A fuse TIN Bus CI BUS1 12 V red red black Fig 20 View from the rear 1 Only wi...

Страница 9: ...the supply line may have to be considered Connect the negative cable to the central earthing system If parts are connected directly to the battery the positive and negative cables must be fused No oth...

Страница 10: ...UNF 3 Fig 25 After installation you must check gas supply line for leaks in accordance with the pressure drop method Do not use matches candles or other sources of ignition when checking for gas leak...

Страница 11: ......

Страница 12: ...e relevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 1800 21 21 2...