background image

10

1

2

3

4

5

6

7

7

6

8

Intended use

The Trumatic S 3002 FS liquid gas heater has been designed
for stationary installation in fixed awning structures.

The equipment must not be used in vehicles (campers)

or coaches. 

The heater has a combustion air/exhaust circuit that is sealed
from the installation area.

Other applications are only permitted after prior consultation
with Truma.

Important operating notes

1. The combustion air intake (2) must be kept free of dirt and
slush.

2. Before switching on the heater in winter, clear all snow from
the cowl (4).

3. Inspect the exhaust duct and all connections at regular inter-
vals, and always in the event of blowback (misfire). It is essen-
tial for the exhaust duct to be installed so that it slopes upwards
over its whole length and is secured with several clamps. Never
place any object on the exhaust duct, since this could result in
damage. The exhaust duct connection to both the heater and
the cowl must be firm and well sealed. It is no longer per-
missible to operate heaters with incorrectly fitted or damaged
exhaust ducts!

4. Never allow the warm air outlet on the heater to be
obstructed in any way.

For instance never hang washing on

or in front of the heater to dry. Misusing your heater in this way
could cause serious damage from overheating. Do not place
flammable objects near the heater. Please follow these guide-
lines in the interest of your own safety.

Due to the design, the heating front case will
become hot during operation. The operator is 
obliged to ensure that due care is taken to protect
third parties (small children in particular).

Trumatic S 3002 FS

Liquid gas heater for free-standing installation
in fixed awning structures

1 Liquid gas heater

Trumatic S 3002 FS

2 Combustion air intake
3 Exhaust duct with

insulating duct

4 Exhaust gas cowl
5 Trumavent fan TEB 2
6 Warm air pipes
7 Warm air outlets
8 Gas supply

Содержание Trumatic S 3002 FS

Страница 1: ...Vorzelten Truma Ger tetechnik GmbH Co KG Postfach 1252 D 85637 Putzbrunn Service Telefon 49 0 89 4617 142 Telefax 49 0 89 4617 159 e mail info truma com www truma com Gebrauchsanweisung Seite 2 Monta...

Страница 2: ...f das Abgasrohr gelegt werden da dies zu Besch di gungen f hren k nnte Das Abgasrohr muss sowohl an der Heizung wie am Kamin dicht und fest angeschlossen sein Hei zungen mit falsch montierten oder bes...

Страница 3: ...ent Gebl se zu betreiben k Handregelung z B f r Ventilation Gew nschte Leistung am Drehknopf einstellen l Aus m Automatikbetrieb Heizen Die Leistung gleicht sich stu fenlos der jeweiligen W rme abgabe...

Страница 4: ...l gegen ber druck ein Manometer mit dem die Dichtheit der Gasanlage berpr ft werden kann Bei Temperaturen um 0 C und darun ter sollten die Druckregeleinrichtungen mit Enteisungsanlage Eis Ex betrieben...

Страница 5: ...Wahl durch Nachbesserung oder Ersatzliefe rung Leistet der Hersteller Garantie beginnt die Garantiefrist hinsichtlich der reparierten oder ausgetauschten Teile nicht von neuem sondern die alte Frist l...

Страница 6: ...EU L nder liegt die Produkt Ident Nummer vor CE 0085AP0325 EWG Typgenehmigung e1 022603 Platzwahl Die Heizung wird freistehend unmittelbar an einer festen Au enwand aufgestellt und muss mit 6 Schraube...

Страница 7: ...aminteil 15 schieben und mit dem Schraub ring 16 festziehen Anschlie end den Schraubring 16 mit der Schraube 17 sichern 2 Von oben die drei beiliegenden Kaminverl ngerungen 18 und das Kamindach 19 auf...

Страница 8: ...eine Batterie ist die Plus und Minusleitung abzusichern Anschl sse 40 in Faston voll isoliert Kfz Flachstecksystem 6 3 mm ausf hren Bei Verpolung der Anschl sse besteht Gefahr von Kabelbrand Au erdem...

Страница 9: ...nschluss M glichkeiten der Heizung an die Gasanlage mit einem Kupplungs Schnellschlussventil KV 8 oder Abzweig Kupplungs Schnellschlussventil AKV 8 an die vorhandene Gas versorgung des Wohnwagens mitt...

Страница 10: ...duct since this could result in damage The exhaust duct connection to both the heater and the cowl must be firm and well sealed It is no longer per missible to operate heaters with incorrectly fitted...

Страница 11: ...Trumavent fan on at all times during heater operation k Manual control e g for ventilation Adjust desired output at the control knob l Off m Automatic operation Heating The output steadily adjusts to...

Страница 12: ...to the appliance including exhaust duct and cowl or the use of spare parts and accessories which are im portant to the function of the heater and which are not original Truma parts as well as the non...

Страница 13: ...r by repair or re placement In the event of manufacturers providing service under warranty the term of the warranty shall not recom mence anew with regard to the repaired or replaced parts rather the...

Страница 14: ...s 90 396 EWG for gas appliances as well as with the associated EC guidelines The product ID No for EU countries is CE 0085AP0325 EEC Type Approval e1 022603 Choice of location The heater is installed...

Страница 15: ...on 15 from the inside and screw to gether using the threaded ring 16 Then secure the threaded ring 16 using the screw 17 2 Screw on the three provided cowl extensions 18 and the cowl 19 from above The...

Страница 16: ...e the plus and mi nus line Connect with faston terminals 40 fully insulated motor vehicle flat connector system 6 3 mm If the connections are interchanged there is a risk of cables burning Furthermore...

Страница 17: ...allow the heater to be removed again for service work Alternatives for connecting heater to gas system to the existing gas supply of the caravan with a KV 8 cou pling quick action stop valve or an AKV...

Страница 18: ...94 30 34 Fax 00358 0 9 84 94 30 30 Truma UK Limited Truma House Eastern Avenue Burton Upon Trent Staffordshire DE13 0BB Tel 0044 0 1283 52 82 01 Fax 0044 0 1283 52 82 02 G Bournas G Efthimiou O E P Ra...

Страница 19: ...Truma Ger tetechnik GmbH Co KG Service Zentrale Postfach 12 52 D 85637 Putzbrunn Postkarte Absender bitte Druckbuchstaben einsetzen Name Vorname Stra e Hausnummer Postleitzahl Wohnort Standort Telefo...

Страница 20: ...S Fl ssiggasheizung zur freistehenden Aufstellung Gaspr fung gew nscht Nur g ltig f r Deutschland Applicable for Germany only Valable seulement pour l Alle magne Festgestellte M ngel bitte kurz beschr...

Отзывы: