background image

4

Always observe the opera ting instructions and “Impor-

tant operating notes” prior to starting! 

The vehicle owner 

is responsible for the correct operation of the appliance!

The installer or vehicle owner must apply the yellow sticker 

with the warning information, which is enclosed with the ap-

pliance, to a place in the vehicle where it is clearly visible to 

all users (e.g. on the wardrobe door)! Ask Truma to send you 

stickers, if necessary.

Control panel with rotary switch

1

3

5

7

9

Trumatic E

1

2

3


5

b

a

d

c

e

g

f

a  = rotary switch (external ring)

b = “Ventilation” rotary switch 

c  = “Off” rotary switch

d = “Heating” rotary switch 

e  = green LED lit “Operation”

f  = rotary knob for room temperature

 

 (1 – 5, 4 

 23 ˚C)

g = red LED lit, red LED blinking “Failure”

Switching on the Heating

Turn on gas cylinder and open quick-acting valve in the gas 

supply line.

Adjust desired room temperature at rotary knob.

Switching the heating on:

Set the rotary switch to (d).

Switching on the Ventilation

Set the rotary switch to (b).

Switching off

Set the rotary switch (a) to the centre (c). If the appliance is 

switched off after a heating phase, the fan can continue run-

ning in order to make use of the residual heat.

If the appliance is not used for a prolonged period of time, 

close quick-acting valve in the gas supply line and turn off 

gas cylinder.

Green LED “Operation”

(under rotary control knob)
When the appliance is switched on (heating or ventilation) 

the green LED must be illuminated (the fan is running). If the 

LED is 

not

 illuminated, possibly check the (main) switch. For 

this purpose observe respective instructions of the vehicle 

manufacturer.

During the heating operation, while the flame is burning, the 

green LED lights up with twice the intensity. This also makes 

it possible to determine the instantaneous switching point of 

the room temperature.

Operating instructions

Fuses

The device and control panel fuses are on the electronic con-

trol unit on the device.

Device fuse (F1): 

3.15 AT – slow – 

Control panel fuse (F3): 

1.6 AT – slow – 

The fine-wire fuse must only be replaced by a fuse of the 

same design.

Red LED “Failure”

Should a failure occur, the red LED is illuminated  

permanently.

 

Possible causes for the failure can be e.g. no gas, insufficient 

combustion air, heavily soiled fan, defective fuse etc.. Deacti-

vate by switching off and then switching on again.

Flash operation

 indicates that the operating voltage is 

too low (charge battery, if necessary) or too high for the 

appliance.

Maintenance

The unit must be checked annually for contamination (dust, 

dirt, debris) by an expert and cleaned if necessary.

Servicing shall be carried out only by authorised 

personnel.

Please contact Dometic Service Centre for service and repairs.

Accessories

1 Time switch ZUE 2

for pre-programming 3 switch-on times within 7 days, 

 including 4 m connecting cable (suitable for 12 V vehicle 

electrical system).

2 Remote sensor FFC 2

monitors the room tem perature independent of the position 

of the control panel (with 4 m connecting cable).

3 Multiple box MSD 

for connecting several accessories (e.g. time switch and 

 remote sensor).

Extension cable for accessories

 

items 1, 3 of 4 m or 10 m (not illustrated).

All electrical accessories are fitted with a connector and can 

be connected individually.

Содержание Trumatic E 2400 E

Страница 1: ...Operating instructions Page 4 Installation instructions Page 7 To be kept in the vehicle Trumatic E 2400 Australia Trumatic E 1 3 5 7 9 1 3 5 7 9 1 2 3 4 5...

Страница 2: ...4 Red LED Failure 4 Maintenance 4 Accessories 4 Technical data 5 Dimensions 5 Truma warranty policy 5 Trouble shooting list 6 Installation instructions Intended use 7 Approval 7 Regulations 7 Choice...

Страница 3: ...ies During the initial operation of a brand new appliance or after it has not been used for some time a slight amount of fumes and smell may be noticed for a short while This will be remedied by runni...

Страница 4: ...the main switch For this purpose observe respective instructions of the vehicle manufacturer During the heating operation while the flame is burning the green LED lights up with twice the intensity Th...

Страница 5: ...only If the product is used for commercial purposes the warranty is 6 months only Where applicable the products must be used on the ap propriate electrical voltage gas type and pressure or fuel source...

Страница 6: ...Over voltage range 15 8 V 16 4 V Charge battery Check the battery voltage and power supply such as e g the charging device Approximately 30 seconds after the heater is switched on the red LED is lit G...

Страница 7: ...vice work and can be removed and installed easily This appliance can be installed without any clearance to com bustible materials providing the surrounding materials will withstand temperatures of up...

Страница 8: ...the corrugations of the exhaust duct 1 for the full width of the clamp 4 as shown in the diagram below Slide exhaust duct over the O Ring 2a on the flue cowl connection fitting 2 up to the collar 3 M...

Страница 9: ...not obstruct the air passage to the appliance 2 Circulating air outside the storage area can be drawn in via a duct piece VR 80 1 80 mm diameter max 100 cm in length and returned to the appliance The...

Страница 10: ...negative Connect the appliance to the fused vehicle electrical system central electrical system 5 10 A using the 2 x 1 5 mm2 cable for lengths over 6 m use 2 x 2 5 mm2 cable Negative cable to central...

Страница 11: ...ompleted guarantee card are to be given to the owner of the vehicle Remove the type plate from the operating and installa tion instructions and affix it at a position on the heater which is clearly vi...

Страница 12: ...ipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50 Facsimile 61 0 3 92 39 10 99 Dometic Pty Ltd Building 3B Clayton Busines...

Отзывы: