9
1 Control panel
2 Power selector switch
3 Time switch ZUC 2 (Accessories)
4 Room temperature sensor
5 Cold water connection
6 Hot water connection
7 Gas connection
8 Hot air outlets
9 Circulating air return line
10 Waste gas discharge
11 Combustion air infeed
12 Electronic control unit
13 Power electronics
14 Overheating switch 230 V
15 Water container (12 litres)
16 Igniter
17 Burner
18 Heat exchanger
19 Overheating protector
20 Heating elements 230 V
21 Electrical safety/drainage valve
Trumatic C 6002 EH
The
Trumatic C 6002 EH
combination device com-
bines the benefits of a sta-
tionary electric heater with
the considerable heating
power of an independent
gas heater.
Irrespective of whether you
just wish to have hot water
in
summer mode
or just
heat or heat and hot water
in winter mode,
3 power
selection options are
available:
–
Gas
only (propane/butane)
for independent operation
–
Electricity
only (230 V)
for stationary operation on a
camping site
– or
Gas and Electricity
(simultaneously).
Summer mode
(hot water only)
Either gas operation or 230 V
electricity operation is used
for preparing hot water. The
water temperature can be set
to 40°C or 60°C.
For
gas operation
the de-
vice automatically selects
the smallest burner setting
at 2000 W. The water tem-
perature is controlled by the
automatic controller, which
is powered by 12 V from the
vehicle battery.
Depending on the fuse pro-
tection at the camping site,
power of 900 W (3.9 A) or
1800 W (7.8 A) can be manu-
ally selected for
electrical
operation.
Mixed operation
(simultaneous gas and
electricity) is not possible.
With this setting the device
automatically selects electri-
cal operation at the selected
power of 900 W or 1800 W.
The gas burner is not enabled.
Winter mode
(heat and hot water)
All 3 energy selection options
can be used for winter de-
ployment.
With
gas operation
the
device automatically selects
the burner setting that is re-
quired (2000 W, 4000 W or
up to 6000 W) depending on
the output requirement (cal-
culated from difference be-
tween selected temperature
and current room tempera-
ture). The circulation fan that
is needed to distribute the
warm air and the automatic
room temperature and safety
monitoring controller are
powered by the vehicle
battery (12 V).
Depending on the fuse pro-
tection at the camping site,
power of 900 W (3.9 A) or
1800 W (7.8 A) can be manu-
ally preselected for
electrical
operation.
If the power require-
ment is higher (e.g.
heating up or low outside
temperatures) gas operation
or mixed operation must be
selected, since the 230 V
electrical heater is only a sec-
ondary heater with maximum
heating power of 1800 W.
In
mixed operation
the full
heating power of 7800 W
(6000 W gas + 1800 W
electricity) is available. This
combination guarantees
rapid heat-up times, even at
extremely low outside tem-
peratures. The heating power
that is required (calculated
from difference between
selected temperature and
current room temperature)
is selected automatically by
the unit. If the power require-
ment is low (e.g. for main-
taining room temperature),
230 V electrical operation is
given priority. The gas burner
is not enabled until the power
requirement is higher, and is
the first to switch off during
heat-up operations.
Heating is always
possible in all operat-
ing modes (gas, electric
and mixed operation) with-
out restrictions, with or
without water.
Function description
Содержание Trumatic C 6002 EH
Страница 52: ......
Страница 54: ...54 Notizen Notes Nota...