Operating instructions
Page 2
To be kept in the vehicle!
Truma LevelControl
Страница 1: ...Operating instructions Page 2 To be kept in the vehicle Truma LevelControl...
Страница 2: ...ortant notes 3 Function description 3 Preparing start up 4 Connect the Truma LevelControl to the Truma iNet Box 4 Securing Truma LevelControl on a gas cylinder 4 LevelControl magnetic foil 7 Replacing...
Страница 3: ...e Truma LevelControl Changes or modifications to this appliance that have not been expressly approved by the department responsible for conformity can invalidate the appliance s operating permit Impor...
Страница 4: ...10 m The range can vary depending on the installation position Start the Truma App Select the menu point Settings Device manager Manage Bluetooth devices Find devices Briefly press the button 5 on th...
Страница 5: ...nger of cut injuries Wear protective gloves con forming to EN 388 ref no 3221 when securing the clamping sheet Do not pull the Truma LevelControl along the gas cylin der base as this can damage the co...
Страница 6: ...nto the gas cylinder base Option A Figure 7 Option B Figure 8 Press the LevelControl clamping sheet into the cylinder base on the opposite side and rotate the swivel plate inwards op tion A or outward...
Страница 7: ...velControl is not forgotten about on the gas cylinder when the gas cylinder is replaced fit the LevelControl magnetic foil in a clearly visible location on the gas cylinder Truma LevelControl Truma Le...
Страница 8: ...ration by selecting the respective Truma LevelControl LevelControl magnetic foil Fit the LevelControl magnetic foil on the new gas cylinder Call up the gas cylinder fill level Call up the Status menu...
Страница 9: ...e Remove the batteries if the appliance is not going to be used for a long period of time No warranty is given for damage caused by leaking batteries Cleaning Clean the Truma LevelControl with a damp...
Страница 10: ...eight with batteries 128 g Interfaces Bluetooth Class 2 2400 MHz to 2483 5 MHz max 4 4 dB 2 75 mW Operating temperature 20 C to 50 C Gas cylinder size 5 kg to 33 kg steel and aluminium gas cylinders G...
Страница 11: ...Union 2014 30 EU Electromagnetic compatibility 2014 34 EU Appliances in potentially explosive areas 2014 53 EU Radio systems 2011 65 EU RoHS The following harmonised standards and other techni cal sp...
Страница 12: ...evelControl does not stick to the gas cylinder Aluminium gas cylinder used clamping sheet available as accessory Gas cylinder on Truma LevelControl Gas cylinder base not deep enough use supporting fee...
Страница 13: ...damaged or missing contact Truma Service Gas cylinder in poor condition or unsuitable replace gas cylinder see Important notes on page 3 Truma LevelControl not installed correctly on cylinder install...
Страница 14: ...89 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com 50000 00011 01 01 2018 Should problems occur please contact the Truma Service Centre or one of our authorised service partners s...