3.38.15 Note that this setting affects only the packet type that the NTS-100 will transmit. The
NTS-100 will receive packets of either type, regardless of this setting.
Changing this parameter will cause a software reset of the NTS-100 module
.
Complete NTS-100 Network Configuration
3.38.16 To review the entire current network configuration of the NTS-100 module, send the
string:
F36<CR>
3.38.17 The unit will respond with (example):
F36 IP:206.54.0.21 SM:255.255.255.240 G:206.54.0.17 N:E<CR><LF>
3.38.18 This response indicates the specific IP address, Subnet Mask, Default Gateway, and
Network Type of the NTS-100 module. Note that the leading zeros within fields of the
dotted decimal addresses are omitted from the IP address, Subnet Mask, and Default
Gateway.
3.38.19 To set all settable network parameters and reset the NTS-100 card, send the string
(example):
F36 IP:206.54.0.21 SM:255.255.255.240 G:206.54.0.17 N:E<CR>
3.38.20 This example provides the NTS-100 card with an IP address, Subnet Mask, Default
Gateway and Network Type. Note that leading zeros may be omitted when entering IP
address, Subnet Mask, and Default Gateway. Any field may be omitted and order is not
significant. Blanks are allowed on either side of a colon. Any legal command set
containing one of the four network parameters will cause a software reset of the
NTS-100.
Clock Type
3.38.21 The synchronization input option determines the clock type. To query the clock type,
send the string:
F36 T<CR>
3.38.22 The unit will respond with:
F36 T:GPS<CR><LF>
For GPS units
F36 T:IRIG<CR><LF>
For IRIG B units
F36 T:1PPS<CR><LF>
For External 1 PPS units
F36 T:ACTS<CR><LF>
For ACTS units
3.38.23 Attempts to set this field will be rejected with a syntax error message.
Clock Accuracy
3.38.24 When the synchronization input option of the NTS-100 is either IRIG-B or External 1PPS,
the accuracy of the timing source driving the IRIG-B or External 1PPS input must be
provided to the NTS-100 so that the appropriate fields in the NTP packet may be