P.1
BRIEF OPERATION GUIDE
For
C
³
V Series
2010 4005 6003
Programmable DC Power Supplies
IMPORTANT SAFETY INSTRUCTIONS
For your own safety and the safety of other people, and to prevent the
product from damage, we suggest you following the instructions not
only for operating and maintaining the product, but also for keeping it in
storage.
Environment
* The product is constructed for indoor use.
* Condensation may occur after the product has been
shipped from cold to warm area. Await the product two hours or longer
to be totally dry before powering on to it.
* Never place the product near water side or in wet area.
* Never place the product under direct sunlight or near heat
source.
* Never block the ventilation openings at the enclosure of the
product.
* Never place any heavy object on the product and severe
impact or rough handling that could lead damage to it.
Storage
* Location: indoor
* Relative humidity: <80%
* Temperature: -10
℃
~ 70
℃
Opteration
* The product is rated at AC input 85~264V, 47~63Hz mains
* Connect the product to an earthed wall receptacle with an
international safety approved power cord.
* Be careful. A power circuit changes from open to short
could cause high current sparks to injure eyes. A power circuit changes
from short to open instantly induce high voltage and arc, to shock
people and injure their eyes.
Service and maintenance
* The product operates with hazardous high voltage ( near
DC 380V or AC 267V) inside. Only qualified personnel can carry out the
service.
* The product still keeps hazardous voltage inside even after
it has been switched off for a while.
P.2
* Before performing any service, disconnect the product from
the mains and await it until no harmful voltage remains at the terminals
of bulk capacitors.
* Please replace the fuse only with the same ratings of
amperage and voltage to avoid risk of fire.
* This is a Class A device which can cause RF interference
within the home.
* The product is operated only when the case is securely
closed and screwed up.
* While operating the product, the wearing of metal or other
conducting jewelry such as chains, bracelets, rings, etc. is not
recommended.
KNOWING ABOUT FRONT PANEL
Explanation to each component
1
Meter &
display
4-digit meter measures and displays the values of
voltage, current and inside temperature.
Also for auxiliary uses of system parameters
setup.
2
Output
key
Press to turn the output on/off.
3 Enter
key
Circulatory modes selection, Up/Down inputs
termination.
4
Up key
Input increments.
5 Down
key Input decrements.
6 V-LED
Green “
V
” denotes unit =”VOLT” for meter display.
Lit state : shows meter display in Reading mode.
Blinking : shows meter display in Setting mode.
7 A-LED
Orange “
A
” denotes unit = ”AMPERE” for meter
display.
Lit state : shows meter display in Reading mode.
Blinking : shows meter display in Setting mode.
8 cc-LED
Red symbol “
cc
”.
Off state : denotes output in constant voltage (CV)
mode.
Lit state: denotes output in constant current (CC)
mode.
9 Output
LED
Green symbol
“ON
”.
Off state : denotes output Off.
Lit state : denotes output On.