background image

 

        

 

Assembly Instructions

 

GK2200T FRAME COMPONENT CHECKLIST 
  

 
 

ITEM 

DESCRIPTION 

QTY 

Cup Holder 

Frame 

Left Upright 

Right Upright 

Left Handrail 

Right Handrail 

Upper Shoulder Cover(Left) 

Upper Shoulder Cover(Right) 

Lower Shoulder Cover(Left) 

Lower Shoulder Cover(Right) 

Handrail cover

left

 

Handrail cover

right

 

 

Содержание GK2200T

Страница 1: ...Assembly Instructions GK2200T TREADMILL ASSEMBLY INSTRUCTIONS Frame Assembly 120V 220V ...

Страница 2: ...ent shock Check with a qualified electrician or serviceman if you are in doubt as to whether the treadmill is properly grounded Do not modify the plug provided with the treadmill if it will not fit the outlet Have a proper outlet installed by a qualified electrician Should you need technical assistance in assembly of your Mobility Research Fitness product contact Mobility Research Technical Suppor...

Страница 3: ...ON QTY A Cup Holder 1 B Frame 1 C Left Upright 1 D Right Upright 1 E Left Handrail 1 F Right Handrail 1 G Upper Shoulder Cover Left 1 H Upper Shoulder Cover Right 1 I Lower Shoulder Cover Left 1 J Lower Shoulder Cover Right 1 L Handrail cover left 2 M Handrail cover right 2 ...

Страница 4: ... d Inner Toothed Washer M8 20 e Truss Hex Screw M8xP1 25x80 Blue Nylon patch 4 f Truss Hex Screw M8xP1 25x40 Blue Nylon patch 8 g Cup Holder Fixing Plate 8 h Bottled Silicon DC 100 30C C 1 i T shaped Wrench 8mmx200mm 1 j Open Spanner 17mmx110mmx2 0t 1 k Hex Wrench 5mmx35mmx160mm 1 l Round head Philips Screw M4xP0 7x35 2 m Nylon nut M4 P0 7 2 n POP Pin 1 ...

Страница 5: ... included o 2 Phillips Screwdriver not included FRAME ASSEMBLY PROCEDURE CAUTION Use caution when assembling treadmill Unpacking and assembling of this treadmill is a two person task NOTE Remove treadmill components from packaging 1 REMOVE MOTOR COVER a Remove two screws and two Motor Decoration Covers from Frame b Remove seven screws and Motor Cover from Frame Fig 1 ...

Страница 6: ...installed b Install Pedestal R D into pedestal support on Frame B while pulling the cable out of pedestal support as shown in Fig 2 1 NOTE Be careful not to pinch cables c Install Pedestal L C into pedestal support on Frame d Using 5mm Hex Key install but do not tighten eight Bolts M8 x 75mm b and Washers M8 as shown in Fig 2 1 Fig 2 ...

Страница 7: ...hematic and Frame Cable Routing Diagram at the end of these Assembly Instructions You may remove from packet to aid in assembly but if you remove we recommend you retain these diagrams with the instructions for future reference Step 3 1 CNTRL Control Cable i Route CNTRL Cable KDCA 2B XL 1063B from pedestal towards small circuit board as shown in Step 3 c picture on page 7 and in Fig 3 1 ii Plug CN...

Страница 8: ...es Once all eight bolts are installed then tighten all bolts You may need to align Pedestal and Console Rack to install first bolt on both sides c Tighten eight Bolts M8 x 75mm b that secure Pedestals to Frame See Fig 2 d Using the 17mm wrench tighten two Hex Head Bolts until secure against Pedestal legs Then tighten two nuts to secure Hex Head Bolts See Fig 4 1 e Place Motor Cover onto frame Usin...

Страница 9: ...Assembly Instructions 8 Fig 4 PEDESTAL TUBING CRADLE Hex Screw Hex Nut ...

Страница 10: ... made from Pedestal Right to Console Rack NOTE All three connections made for any Console model b CNTRL Control Cable i Connect CNTRL Cable p n KDCA 2B XL 1063B from Pedestal R to CNTRL Cable p n KDCA 1 XL 1053A from Console Rack See Fig 5 1 NOTE 10 pin connector is polarized Insert properly Fig 5 ...

Страница 11: ...Assembly Instructions 10 6 HANDRAIL INSTALLATION a Insert Handrails E F onto Pedestals and secure with four Bolts M8 x 80mm e and Internal Tooth Washer M8 d using 5 mm Hex Key Fig 6 ...

Страница 12: ...R COVER TOP INSTALLATION a Using a Phillips screwdriver install Shoulder Cover Top pieces Left G and Right H with three Screws M4 x 10mm c on each side as shown in Fig 7 CAUTION Make sure cabling is NOT pinched during installation Fig 7 ...

Страница 13: ...ALLATION a Using a Phillips screwdriver magnetic tip option can be used install Shoulder Cover Bottom pieces Left G and Right H with five Screws M4 x 10mm c on each side as shown in Fig 8 CAUTION Make sure cabling is NOT pinched during installation Fig 8 ...

Страница 14: ...ht M handrail covers with the ribbing plate into the square hole in the left and right handrail as shown in Fig 9 1 b Tighten the left L and right M handrail cover using screw i and nylon nut m c Fasten POP Pin n into the adjustable console neck assembly Square hole Ribbing Plate ...

Страница 15: ... the Circuit Breaker will operate the Circuit Breaker will trip and open the circuit If this should occur please wait 10 minutes and then reset the Circuit Breaker by cycling the Circuit Breaker to the off position 0 then back to the on position l If it does not reset or the Circuit Breaker operates again please contact Light Gait Service department at 1 800 332 9255 Fig 9 1 GK2200T Treadmill Fron...

Страница 16: ...e below SAFETY KEY AS SHIPPED b Unwind safety key and cord from plate c Attach Safety Key magnet to front of Center Pod as shown below d Attach Safety Key clip to plate located on Console Rack when not working out e Attach clip to clothing at the beginning of any workout CAUTION Read treadmill Owners Manual before attempting any workout ...

Страница 17: ...Assembly Instructions 16 SAFETY KEY INSTALLED CLIP MAGNET LANYARD ATTACHED TO PLATE PLATE ...

Страница 18: ...Assembly Instructions 17 Electrical Schematic www LiteGait com 800 332 9255 1 480 829 1727 2012 Mobility Research Inc Specifications subject to change 09252012 ...

Отзывы: