LCD display problems (XRS EID Stick Reader only)
Symptom
Cause
Solution
The LCD looks
washed out.
This can be caused by
extreme temperatures.
Adjust the
CONTRAST
in the stick reader settings. See
Changing the stick reader settings on the stick reader
itself
on page 33.
LCD display has
missing pixels.
Faulty Display FFC (flat
flexible circuit) cable .
Test the LCD. See page 20.
Try replacing the Display FFC (flat flexible circuit) cable.
See page 32.
Faulty display module.
Replace the display module. See page 29.
LCD not working at
all.
Faulty Display FFC (flat
flexible circuit) cable .
Try replacing the Display FFC (flat flexible circuit) cable.
See page 32.
Faulty display module.
Replace the display module. See page 29.