Battery charging 

 

6

Warning!

   

Ensure that the battery is disconnected from the energizer 

before connecting the battery to any mains-operated 
(line-operated) battery charging device. Failure to 
observe this precaution could result in damage to the 
energizer and possible electrocution. 

When charging, ensure that there is adequate ventilation 

to allow gases to disperse. 

 

 

A battery-only installation has unique requirements. Regular 

recharging of the battery is essential. Use a suitably rated 
battery charger to recharge the battery. Refer to the battery 
manufacturer’s recommendations. 

 

Disconnect the battery from the energizer. 

Attach the positive (+) battery charger lead to the 

positive terminal of the battery, and the negative (–) 
battery charger lead to the negative terminal on the 
battery. 

Insert the battery charger's input power plug into a mains 
or line socket and turn on the power supply. 

After the battery is charged, disconnect it from the battery 
charger before connecting it to the energizer. 

Caution!  

Over-charging the battery will reduce its life. Do 

not exceed the recommendations of the battery 
manufacturer on recharging the battery from a mains-
powered (line-powered) source. 

A correctly installed solar energizer system requires very little 
battery maintenance. The solar panel selected should be 
sufficient to maintain the battery at full or near-full charge. 

 

Battery care and maintenance 

• 

• 

• 
• 

• 

• 

• 
• 
• 

House the battery in a suitably designed battery box, if 
the battery is likely to be exposed to the weather. 
When not in use, keep the battery as fully charged as 
possible. 
Recharge a discharged battery as soon as possible. 
Batteries should be stored fully charged and recharged at 
regular intervals (every 8 weeks) 
Inspect the battery regularly to ensure that the electrolyte 
level does not fall below 12 mm (½") above the surface 
of the battery plates.  
Fill using deionised, distilled or rain water. Do not 
overfill. Refer to the battery manufacturer’s 
recommendations for more information. 

Battery safety 

Ensure that the battery is well ventilated when recharging. 
Avoid temperatures greater than 50 °C (120 °F). 
Ensure the battery is not exposed to naked flame or 
sparks. 

Building a permanent electric 
fence 

Components of an electric fence 

An electric fence system comprises the following elements: 

An energizer.

 

• 
• 

• 

• 

An earth system. 

This comprises a number of metal rods 

inserted into the ground, which are connected to the 
Fence earth terminal on the energizer. 

Speedrite insulated underground cables. 

Used to connect 

the energizer to the earth and fence. 

An insulated fence. 

Connected to the Fence output 

terminal of the energizer. Fences can be made to a variety 
of designs (see below). 

 

 

Other useful components that can be added: 

 

Cut-out switches. Installed at regular intervals, these 
allow you to isolate sections of the fence for repair. 
Lightning diverter kit. Used to minimise the damage 
to your energizer from lightning conducted down the 
fence line. 

 

Typical installation 

The animal receives a shock when it completes a circuit 

between the fence and the earth system. The fence below has 
all live wires and requires conductive soils. These fences are 
often referred to as 'all-live' or 'earth-return' fences. 

 

 

Содержание speedrite Delta 1B

Страница 1: ...TM speedrite by WARNING READ ALL INSTRUCTIONS Delta Battery Energizer USER MANUAL ELECTRIC FENCING FOR THE SERIOUS FARMER...

Страница 2: ...s of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying r...

Страница 3: ...se lightning striking your fence will be conducted to all other devices Symbols that may be on your energizer To reduce the risk of electric shock the energizer should be opened or repaired only by qu...

Страница 4: ...nal of the battery and the black clip to its negative terminal Interior installations For interior installations make sure the energizer and battery are level Mount them above floor level and out of r...

Страница 5: ...all times Auto The energizer will adjust its pulse speed to conserve battery power depending on the battery charge level See the table below Fast nocturnal The energizer will pulse fast at night and s...

Страница 6: ...ctly and is clean If the problem recurs the panel may be inadequate or faulty Take the entire system to an authorised service agent for assessment Red light on Low battery charge level Recharge the ba...

Страница 7: ...r Fast Pulse Half Power Fast Pulse 70 mA 35 mA 70 Ah 35 Ah Delta 2B Full Power Fast Pulse Half Power Fast Pulse 140 mA 70 mA 140 Ah 70 Ah Delta 3B Full Power Fast Pulse Half Power Fast Pulse 340 mA 17...

Страница 8: ...to the weather When not in use keep the battery as fully charged as possible Recharge a discharged battery as soon as possible Batteries should be stored fully charged and recharged at regular interv...

Страница 9: ...peedrite distributor which design best suits your needs Some suggested fence configurations are below Cattle and horses 10 15 m 33 49 spacing posts only 15 20 m 49 65 spacing with droppers Sheep goats...

Страница 10: ...imum number of 2 m 6 6 earth rods recommended for an earthing system Energizer Earth rods Delta 1B 0 5 J 1 Delta 2B 1 0 J 2 Delta 3B 2 5 J 3 Test the earth system using the following procedure 1 Turn...

Страница 11: ...ally isolated from the electric fence Physical barrier A barrier not less than 1 5 m 5 high intended to prevent inadvertent contact with the pulsed conductors of the electric fence Physical barriers a...

Страница 12: ...lectric animal fence wires are installed near an overhead power line their height above the ground shall not exceed 3 m 10 This height applies to either side of the orthogonal projection of the outerm...

Страница 13: ...ood condition and the voltage is still below 4 kV talk to your Speedrite distributor They will help you identify whether recent extensions to your fence a poor fence layout or soil conditions may be c...

Страница 14: ...panel Current Consumption Fast Full Power Fast Half Power 70 mA 35 mA 140 mA 70 mA 340 mA 170 mA Maximum Output Voltage 7 9 kV 8 4 kV 8 4 kV Maximum Output Energy 0 5 J at 700 1 0 J at 400 2 5 J at 20...

Страница 15: ......

Страница 16: ...TM speedrite by SAVE THESE INSTRUCTIONS www speedrite com...

Отзывы: