background image

 

2

 

ENGLISH 

The Energizer Monitor Unit 

Congratulations on your recent purchase of an Energizer Monitor Unit electric fence security 
system. 
The unit is a combined electric fence energizer and alarm system designed primarily for security 

fencing applications.  When armed, the unit continuously checks the fence voltage and triggers an 
alarm if the fence voltage falls outside of preset limits (e.g. when an intruder attempts to breach or 
climb the fence). 
The system can provide a high level of security to a wide range of installations, and includes the 
following features: 

• 

Easy to use. 

• 

Powerful electric fence energizer with up to 4 joules output energy. 

• 

Adjustable fence voltage up to 12,000 volts. 

• 

Reduced false alarms, due to a unique dynamic fence monitoring option that distinguishes 
sudden fence voltage changes from slow changes caused by environmental degradation. 

• 

Provision for up to four Keypads and/or Keyswitches (altogether). 

• 

Full gate access control using low voltage cabling for improved system reliability. 

• 

Outputs for auxiliary warning equipment, and a siren up to 15 W. 

• 

Easy connection to a tele-dialler or your master alarm system. 

• 

An internal battery keeps the unit working during a power failure. 

• 

Compatible with solar power installations. 

• 

‘Flash’ computer memory allows easy on-site software upgrades. 

• 

Flashing lamp warnings of poor battery and loss of mains power. 

• 

Low voltage isolated mains power pack for improved safety. 

• 

Many system configuration option settings available for maximum flexibility. 

• 

Built-in fault diagnostics for efficient servicing. 

 

Getting Started 

The unit has a set of configuration options that can be set using a Keypad.  These are usually set by 
the installer, but may be re-configured later if required. 

 

Содержание Electric Fence Security System

Страница 1: ...e trademarks of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical pho...

Страница 2: ...t distinguishes sudden fence voltage changes from slow changes caused by environmental degradation Provision for up to four Keypads and or Keyswitches altogether Full gate access control using low vol...

Страница 3: ...ator lamps these allow the unit to be installed on its own without a Keypad or Keyswitch It has the same full range of features and customisable settings as provided on the Premium but these are set b...

Страница 4: ...factory default OPIN is 5555 The Keypad will give a short beep to confirm each key press a long high pitched beep after each successful command sequence and a long low pitched beep after an invalid c...

Страница 5: ...right until a fast beeping is heard 3 Return the key back to the upright position and remove Disarming using the Keypad To disarm the system enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY...

Страница 6: ...tering Monitor mode using the Keypad To set Monitor mode enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 Monitor using User PIN U P I N or Owner PIN O P I N Note that in Monito...

Страница 7: ...KEY 2 KEY 3 KEY 4 KEY 5 Return to Standby using User PIN U P I N or Owner PIN O P I N The system will disarm the Armed lamp will turn off and the Pulse lamp will stop flashing Tip You may instantly ac...

Страница 8: ...Each subsequent activation of the alarm will normally cause the siren to be re triggered The siren can be silenced immediately by the user without deactivating the electric fence security system This...

Страница 9: ...to your assistance The siren will not time out and will continue until you exit Panic mode Note A panic alarm cannot be raised using the Keyswitch Exiting Panic mode Exiting Panic mode using the Keys...

Страница 10: ...ce of your installer On Mains power on and battery good Off Normal operation if armed system is secure Flashing Fence alarm condition present On Fence currently secure but the fence alarm has previous...

Страница 11: ...ch where fitted If the gate has been left open after a short period has elapsed half of the exit delay time the chime will sound once every 10 seconds as a warning Tamper alarm If someone tampers with...

Страница 12: ...uired to change these PIN numbers whereas the UPIN cannot do this even for the UPIN itself Setting the UPIN To set the UPIN enter the current OPIN followed by the command and then key in the new UPIN...

Страница 13: ...lashing fast Additionally the beeper will sound in the Keyswitch and Keypad Ask your service agent for assistance If the supply cord is damaged it must only be replaced by your service agent in order...

Страница 14: ...have it checked and repaired promptly by your service agent to ensure system integrity The Power Pack supply cord cannot be replaced If the cord is damaged the whole Power Pack should be replaced Ens...

Страница 15: ...d their ancillary equipment shall be installed operated and maintained in a manner that minimizes danger to persons and reduces the risk of persons receiving an electric shock unless they attempt to p...

Страница 16: ...ge not exceeding 1 000 V 15 m for power lines operating at a nominal voltage exceeding 1 000 V A spacing of 2 5 m shall be maintained between uninsulated electric security fence conductors or uninsula...

Страница 17: ...suitable for use outdoors and is of a type with a minimum degree of protection IPX4 Figure 1 Symbol for warning sign Warranty This product is warranted against faulty material and workmanship for a p...

Отзывы: