background image

 

17

 

• 

Ensure that all mains operated, ancillary equipment connected to the electric security fence circuit provides 

a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the 
energizer. 

NOTE: 

Ancillary equipment that complies with the requirements relating to isolation between the fence 

circuit and the supply mains in Clauses 14, 16 and 29 of the standard for the electric fence energizer is 
considered to provide an adequate level of isolation. 

• 

Mains supply wiring shall not be installed in the same conduit as signalling leads associated with the electric 
security fence installation. 

• 

Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified 

by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of 
protection IPX4.

 

 

Figure 1 – Symbol for warning sign

 

 

Warranty 

This product is warranted against faulty material and workmanship for a period from the date of 
purchase. If a warranted defect occurs, return this product with proof of purchase to the place of 
purchase. Details of warranty periods and other terms applying are available at the place of 
purchase or at 

www.tru-test.com

Note:  

-  No responsibility is accepted for any accident or damage caused subsequent to any tampering 

with or modification to or misuse of this product, including (but not limited to) alterations 
made by anyone other than Tru-Test or its agents. 

-  To the maximum extent permitted by law, this warranty is exclusive, personal to you and in lieu 

of all other warranties, representations or conditions relating to this product (whether express 
or implied and whenever arising) whether originating by statute, law, trade, custom or 
otherwise. 

 

 

Содержание Electric Fence Security System

Страница 1: ...e trademarks of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical pho...

Страница 2: ...t distinguishes sudden fence voltage changes from slow changes caused by environmental degradation Provision for up to four Keypads and or Keyswitches altogether Full gate access control using low vol...

Страница 3: ...ator lamps these allow the unit to be installed on its own without a Keypad or Keyswitch It has the same full range of features and customisable settings as provided on the Premium but these are set b...

Страница 4: ...factory default OPIN is 5555 The Keypad will give a short beep to confirm each key press a long high pitched beep after each successful command sequence and a long low pitched beep after an invalid c...

Страница 5: ...right until a fast beeping is heard 3 Return the key back to the upright position and remove Disarming using the Keypad To disarm the system enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY...

Страница 6: ...tering Monitor mode using the Keypad To set Monitor mode enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 Monitor using User PIN U P I N or Owner PIN O P I N Note that in Monito...

Страница 7: ...KEY 2 KEY 3 KEY 4 KEY 5 Return to Standby using User PIN U P I N or Owner PIN O P I N The system will disarm the Armed lamp will turn off and the Pulse lamp will stop flashing Tip You may instantly ac...

Страница 8: ...Each subsequent activation of the alarm will normally cause the siren to be re triggered The siren can be silenced immediately by the user without deactivating the electric fence security system This...

Страница 9: ...to your assistance The siren will not time out and will continue until you exit Panic mode Note A panic alarm cannot be raised using the Keyswitch Exiting Panic mode Exiting Panic mode using the Keys...

Страница 10: ...ce of your installer On Mains power on and battery good Off Normal operation if armed system is secure Flashing Fence alarm condition present On Fence currently secure but the fence alarm has previous...

Страница 11: ...ch where fitted If the gate has been left open after a short period has elapsed half of the exit delay time the chime will sound once every 10 seconds as a warning Tamper alarm If someone tampers with...

Страница 12: ...uired to change these PIN numbers whereas the UPIN cannot do this even for the UPIN itself Setting the UPIN To set the UPIN enter the current OPIN followed by the command and then key in the new UPIN...

Страница 13: ...lashing fast Additionally the beeper will sound in the Keyswitch and Keypad Ask your service agent for assistance If the supply cord is damaged it must only be replaced by your service agent in order...

Страница 14: ...have it checked and repaired promptly by your service agent to ensure system integrity The Power Pack supply cord cannot be replaced If the cord is damaged the whole Power Pack should be replaced Ens...

Страница 15: ...d their ancillary equipment shall be installed operated and maintained in a manner that minimizes danger to persons and reduces the risk of persons receiving an electric shock unless they attempt to p...

Страница 16: ...ge not exceeding 1 000 V 15 m for power lines operating at a nominal voltage exceeding 1 000 V A spacing of 2 5 m shall be maintained between uninsulated electric security fence conductors or uninsula...

Страница 17: ...suitable for use outdoors and is of a type with a minimum degree of protection IPX4 Figure 1 Symbol for warning sign Warranty This product is warranted against faulty material and workmanship for a p...

Отзывы: