TRU-SCAPES TS-B1 Series Скачать руководство пользователя страница 1

INSTALLATION AND SAF

ET

Y INSTRUCTIONS 

READ THESE INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION 

This fixture is intended for installation in accordance with the National Electric Code (NEC) and 

Local code specifications. Failure to adhere to these codes and instructions may result in serious 

injury and/or property damage and will void the warranty.

 

1)

WARNING: 

This fixture is not to be installed within 10 feet (3M) of a pool, spa or fountain.

2) This fixture is to be used only with a power unit (transformer) rated a maximum of 300 W (25 AMPS) 15 volts.

3) The #18 ga. fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6" (152mm) beneath the surface of the ground.  Contact your Tru-Scapes

Dealer for direct burial wire

5) Wiring connections must be made with provided wire nuts or other equally suitable connector for the application. Do not

exceed manufacturers’ wiring combination specifications for size and quantity of conductors.

CAUTION - WHEN INSTALLING ANY LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE TAKEN 
TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.  WHEN MAINTAINING THE FIXTURES, BE SURE TO 

REMOVE LEAVES, PINE NEEDLES, GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT 

BULB, LENS, OR BODY OF THE FIXTURE.

 

ASSEMBLY AND INSTALLATION 

Part Numbers TS-B1xx-xxx, TS-B3xx-xxx 

1) TURN OFF POWER.
2) At desired location, hammer stake (C)

into ground. To avoid damage to stake,
place a board on top of stake while
hammering.

3) Clear away area in ground at wireway

slot (B) in top of stake (A).

4) Lay 12V cable into wireway slot (B) and

screw stem (A) into stake (C). If
assembly is not straight, adjust by
pushing or pulling on stake only, not the
stem.

5) Make wire connections using supplied

wire nuts.

ASSEMBLY AND INSTALLATION 

Part Numbers TS-Axxx-xxx, TS-A2xxx-xxx 

1)

TURN OFF POWER.

2)

Determine location of
each fixture before wall is
installed.

3)

DO NOT install in walls
where the capstones
overhang the wall less
than ¾” (19mm)

4)

Insert stainless steel
mounting plate between
layers of hardscape
blocks.  Use adhesive or mortar if desired.

5)

Route the fixture wire through the wall to using notches cut into block as needed.

6)

Make wire connections using supplied wire nuts.

ASSEMBLY AND INSTALLATION 

Part Numbers TS-B2xx-xxx 

Lamp fixture is NOT submersible and adequate dranage must be provided 
during installation.  It is recommended that fixture be surrouded by 3 to 4 inches 
of pea gravel or sand to assure proper drainage.  Top of fixture must remain 
above grade so rain and irrigation water can not accumulate for a long time 

1.

TURN OFF POWER

2.

Dig a hole according to the fixture dimension, allowing 3-4” of pea
gravel or sand to surround it.

3.

Make wire connections with supplied wire nuts

4.

Place fixture in hole and backfill with pea gravel or sand

Отзывы: