background image

 

ʬ

Function Instruction

5

 

S1  S2  S3

S4  S5  S6

STOP

BRAKE

INT-VR

EXT-VR

ł

Ń ń Ņ

E F G H  I

J K L M

POWER

SPEED2

SPEED CONTROLLER

SPEED1

SS

SD

ŔIJġġŔijġġŔĴ

BRAKE

STOP

ŔĵġġŔĶġġŔķ

INT-VR

EXT-VR

0RXQWLQJ
+ROH

N

0RXQWLQJ
+ROH

3111

2611

2111

611

1

1!

3!

5!

7!

9

Speed(r/min)

21

:

9

8

7

6

5

4

3

2

1

1

2

Internal(external) speed control Scale 

(Scale Diagram)

Instruction

Ą

Internal Speed control

Speed range:

60Hz - 90~1700r/min

ƞ

50Hz - 90~1400r/min

ƞ

Rotating clokwise with internal

knob will be faster. It can also

control speed with VR in 

long distance occasion.

36

31

26

21

6

1!!!

Slow

 Start(sec/1600r/min)

21

:

9

8

7

6

5

4

3

2

1

1

2

Slow Start time     Scale

Ą6/2:67$57

21

:

9

8

7

6

5

4

3

2

1

Ą6/2:'2:1

It will have effect on start time

(unload)and two parts of speed

control(low to high speed)

Rotating clockwise with SS knob

will lengthen the START time.

Original set is scale“0”

(No SLOW START function) 

Example of
Slow Start/Slow Down

˛

No Slow Start/Slow Down

Operate with TE controller
(Slow Start/Slow Down)

Speed 2
Internal 
control

Slow Start

Control

Slow Down

Control

S1-S2 short circuit (ON)  

STOP

S1-S2 open circuit (OFF)

RUN

S1-S3 short circuit(ON)  

BRAKE

S1-S3 open circuit(OFF)

RUN

S4-S5 short circuit(ON)

Use

internal control to set speed

S4

S6 link to external VR to

set speed(Premise is open
circuit between S4-S5)

6

36

31

26

21

6

1!!!

1

2

Instruction

Instruction

Speed 1
Internal 
control

(Scale Diagram)

(Scale Diagram)

6

Slow Down time     Scale

Slow

 Stop(sec/1600r/min)

It will have effect on stop time

(unload)and two parts of speed

control(high to low speed)

Rotating clockwise with SD knob

will lengthen the STOP time.

Original set is scale“0”

(No SLOW DOWN function) 

7

Содержание TE31 Series

Страница 1: ...sy Controlling Slow Start SS 濕Slow Down SD 濕Instantaneous Brake Internal and external speed control DIN rail installation of European standard Induction Motor Speed Controller TE31 TE32 Series User s Mannual 7 71 9 ʰScan to view online 1 ...

Страница 2: ...e caused by earthquake fire artificial accident please set and fix it for confirmation Prevent electric shock injury fire trouble and damage Install an external emergency stop circuit to turn the power off in the instant halt of operation Prevent electric shock injury fire trouble and damage Connect the Brake and Motor to ground Prevent electric shock Neither reach nor touch the Brake terminals wh...

Страница 3: ... the appointed voltage Prevent injury fire electric shock Do not cut in or off the power frequently It may cause trouble Do not use damaged Brake or Motor It may cause injury fire Do not put obstacle around Brake and Motor or it ll be airless It may cause scald fire Please have the cause troubleshooting as tripping and restart after safety confirming Prevent injury Have an expert execute maintenan...

Страница 4: ...OLLER SPEED1 SS SD ŔIJġġŔijġġŔĴ STOP BRAKE ŔĵġġŔĶġġŔķ INT VR EXT VR Risk of injury and electric shock Read the manual and follow the safety Instructions before use Wait to touch an electronic device for 1 minute after disconnecting power supply Ensure proper earth connection WARNING Dimension 4 ...

Страница 5: ...ʬ QVWDOODWLRQ 3 Using DIN rail in 35mm size Using two screws M4 No attachment Min 15mm fastening to installing hole of two sides of controller 35mm 5 ...

Страница 6: ...ow speed BRAKE O N O FF O N O FF O N O FF C W RUN Internal Internal External CW CW BRAKE CCW CCW CW Clockwise CCW Motor Operation RUN STOP RUN BRAKE QWHUQDO VSHHG WHUQDO VSHHG CW CCW Input STOP STOP RUN BRAKE SLOW START SLOW DOWN 7ZR 6SHHG 6ZLWFKLQJ 6723 Sequence diagram Low speed Counterclockwise QWHUQDO WHUQDO External 6 ...

Страница 7: ...wo parts of speed control low to high speed Rotating clockwise with SS knob will lengthen the START time Original set is scale 0 No SLOW START function Example of Slow Start Slow Down No Slow Start Slow Down Operate with TE controller Slow Start Slow Down Speed 2 Internal control Slow Start Control Slow Down Control S1 S2 short circuit ON STOP S1 S2 open circuit OFF RUN S1 S3 short circuit ON BRAK...

Страница 8: ...FORFNZLVH Frame ground SW1 SWITCH type AC250V 10A AC POWER Capacitance SW1 Power Filter Fuse Power filter type YG10T5 01 AC125 250V 10A Fuse type TE31 AC250V 10A TE32 AC250V 5A SRZHU LQSXW VZLWFK LQVWDOOLQJ Please use above AWG18 for AC power input and extending wire Its limitation is 10M between Motor and controller Capacitance installing Please confirm that if X RI capacitance is same as Motor S...

Страница 9: ...R SPEED1 SS SD ŔIJġġŔijġġŔĴ BRAKE ŔĵġġŔĶġġŔķ INT VR EXT VR STOP STOP 6 澽6 W SH ERYH 9 P RUN BRAKE STOP QWHUQDO 3DUW URWDWLRQ 澿As two part of speed control Part 1 use SPEED 1 to control and Part 2 use SPEED 2 to control 9DULDEOH 5HVLVWDQFH 95 ʈ W SH 7 581 17 581 澿1RWLFH ZKHQ XVLQJ YDULDEOH UHVLVWDQFH WKH 63 PXVW EH DGMXVWHG WR ERWWRP FRXQWHUFORFNZLVH 2U LW ZLOO DIIHFW WKH UDQJH IRU VSHHG FRQWURO 6FDO...

Страница 10: ...otating Direction Counterclockwise Clockwise Switching 6 W SH 9 W PXVW FRQQHFW VSDUN NLOOHU LQ SDUW RI 5HOD DQG VZLWFK DV FKDQJLQJ DQG LWKRXW VSDUN NLOOHU WKH UHOD PLJKW EH ROG GDPDJHG DQG FDXVHG FRQWUROOHU EXUQHG FFHVVRULHV 5 1 X ʈ AC POWER Power Filter Capacitance Blue Black Yellow White Blue Blue Capacitance Fuse AC POWER Power Filter Yellow 10 ...

Страница 11: ...orque If you need holding torque you can choose Electromagnetic Brake Motor ʬDon t use controller as open collector to control TE31 32 in RUN STOP BRAKE INTERNAL EXTERNAL to control speed ʰImportant Notice ʰPlease inquiry with local officer or distributor to choose product Made in Taiwan www troy com tw ʰResponsibility of environment protection We place important on spreading environment protectio...

Отзывы: