![Troxler EGauge 4590 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/troxler/egauge-4590/egauge-4590_manual-of-operation-and-instruction_1172540071.webp)
Model 4590
5–3
C
C
o
o
u
u
n
n
t
t
T
T
i
i
m
m
e
e
The gauge provides three different count times for taking
measurements. To change the count time, see page 3–10.
A two-minute count time is recommended for the
density measurement on most materials.
For the EGauges that offer the 9-12-inch depth
positions, a minimum 3-minute count is required for the
depths below 8 inches.
Содержание EGauge 4590
Страница 9: ......
Страница 18: ...xvi NOTES...
Страница 24: ...1 6 Figure 1 4590 Gauge and Standard Accessories...
Страница 26: ...1 8...
Страница 70: ......
Страница 94: ...6 4...
Страница 104: ......
Страница 112: ...8 10 Complete Pairing on the Bluetooth enabled device A Confirmation screen displays once pairing is successful...
Страница 164: ......
Страница 168: ......
Страница 171: ...Model 4590 F 3 Standard Count Log Gauge Serial Number Date DS BGD Date DS BGD...
Страница 174: ......
Страница 186: ...Notes NOTES...