Model 3430
5-5
DRIFT TEST
If the stat test has already been performed (and passed), but gauge
readings seem to drift between tests, the
drift test
can check the
long-term drift of the 3430 gauge.
A drift test consists of five 4-minute counts taken approximately 3
to 8 hours after completion of a stat test
with no movement of the
gauge between tests.
Pass/fail limits are set using the percent
difference between the average of the stat and drift test results. If the
percent difference exceeds 0.5% for density or 1% for moisture, the
drift test fails.
NOTE
The gauge should not be turned off between the stat test
and drift test. The stat test must be current.
In addition, the gauge must not be moved between the
stat and drift tests to eliminate possible failure due to
positioning changes.
With the gauge still in the standard count position (on the reference
standard block), press
〈
SPECIAL
〉
.
From the
Special
functions, select the
Drift Test
feature by pressing
the down arrow three times and
〈
START/ENTER
〉
.
To begin the five counts, press
〈
START/ENTER
〉
.
As with the stat test, the gauge indicates the count progress during
the drift test.
press START for
20 min Drift Test
– DRIFT TEST –
Rdg.#:xx
xxx sec
S
P
E
CI
AL
F
UNCT
IO
N
S
Содержание 3430-M
Страница 9: ......
Страница 14: ...xii NOTES...
Страница 19: ...Model 3430 1 5 Figure 1 1 Model 3430 Gauge and Accessories INTRODUCTION...
Страница 22: ...1 8 NOTES...
Страница 25: ...Model 3430 2 3 Figure 2 1 Direct Transmission Geometry Figure 2 2 Backscatter Geometry OPERATION THEORY...
Страница 26: ...2 4 Figure 2 3 Backscatter Surface Density Effects Top Layer Effect Curves...
Страница 28: ...2 6 Figure 2 4 Effect of Moisture on Depth of Measurement...
Страница 48: ...3 20 NOTES...
Страница 62: ...4 14 NOTES...
Страница 66: ...5 20 D xxxx M xxxx Use keys Moist R xxxx to view data Moist Avg xxxx to view data...
Страница 88: ...A 14 NOTES...
Страница 111: ...Model 3430 C 17 Figure C 2 3430 Gauge Assembly MAINTENANCE...
Страница 113: ...Model 3430 C 19 Figure C 3 3430 Gauge Base Mechanical Assembly Figure C 4 3430 Source Rod Handle Assembly MAINTENANCE...
Страница 115: ...Model 3430 C 21 Figure C 5 3430 Gauge Preamplifier Assembly MAINTENANCE...
Страница 117: ...Model 3430 C 23 Figure C 6 3430 Gauge Scaler Assembly MAINTENANCE...
Страница 128: ...E 2 Date MS DS Date MS DS STANDARD COUNT LOG Gauge Serial Number...
Страница 129: ...Model 3430 E 3 Date MS DS Date MS DS STANDARD COUNT LOG Gauge Serial Number STANDARD COUNT LOG...
Страница 130: ...E 4 Date MS DS Date MS DS STANDARD COUNT LOG Gauge Serial Number...
Страница 140: ...Index 8 NOTES...
Страница 141: ...Model 3430 Warranty 1 NOTES WARRANTY...