Trotec TWP 4005 E Скачать руководство пользователя страница 1

TRT-BA-TWP4005E-TC-001-EN

TWP 4005 E

EN

OPERATING MANUAL

SUBMERGED CLEAR WATER
PUMP, NEAR-GROUND
SUCTION

Содержание TWP 4005 E

Страница 1: ...TRT BA TWP4005E TC 001 EN TWP 4005 E EN OPERATING MANUAL SUBMERGED CLEAR WATER PUMP NEAR GROUND SUCTION...

Страница 2: ...ut your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual...

Страница 3: ...No liability is accepted for damages resulting from improper use In such a case any warranty claims will be voided also Safety Read this manual carefully before starting or using the device Always sto...

Страница 4: ...rving the device s power input Before using cable drums always unroll the cable completely Check the cable for damage Before performing any work on the device in case of leaks in the water system befo...

Страница 5: ...y networks The device is not suitable for pumping potable water The device must not be used for aggressive abrasive caustic combustible or explosive pumping media e g brine sandy water food cleaning a...

Страница 6: ...emergency disconnect the device from the mains feed in Switch the device off and disconnect the power cable from the mains socket Hold onto the mains plug while doing so 2 Do not reconnect a defective...

Страница 7: ...ring Technical data Parameter Value Model TWP 4005 E Article number 4 610 000 005 Max feed rate 7000 l h Max pump height 7 5 m Max submersion depth 7 m Max water temperature 35 C Power supply 230 V 24...

Страница 8: ...ght position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from...

Страница 9: ...er Please note that the conveying capacity declines with an increasing length of the water discharge line Hose line Info If required you can cut the reducer 7 off at the desired diameter At delivery t...

Страница 10: ...loat switch 4 and its position in the float switch locking device 3 Please observe the following information regarding the float switch 4 Make sure that the float switch 4 always has enough clearance...

Страница 11: ...cal data Check the mains socket for its proper condition and sufficient fusing Make it impossible for moisture to reach mains plug or socket There is a risk of electric shock Warning of electrical vol...

Страница 12: ...revents the water from flowing back from the line through the device at the end of the pumping process Manual operation You can also use the device in manual operation In manual operation it is possib...

Страница 13: ...ice has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power...

Страница 14: ...up the device Check the hose diameter and the pump height An excessive pump height paired with a small hose diameter can cause a reduction of the conveying capacity Check whether the hose line is kin...

Страница 15: ...nity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate collection of wast...

Страница 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: