Operating Manual – Dehumidifier TTK 75 E

5

Danger!

Dangers can occur at the device when it
is used by untrained people in an unpro-
fessional or improper way! Observe the
personnel qualifications!

Behaviour in the event of an emergency

1. Disconnect the device from the mains power in an

emergency.

2. Do not reconnect a defective device to the mains

power.

To make the device easier to transport, it is fitted with
lateral carry handles and wheels.

Before

 transporting the device, proceed as follows:

1. Switch off the device at the mains switch (see

chapter Operating elements).

2. Remove the mains plug from the mains socket.

Do not use the power cable to drag the device!

3. Empty the condensation tank. Check for dripping

condensation.

After

 transporting the device, proceed as follows:

1. Set the device in an upright position after trans-

port.

2. Wait one hour before switching the device on!

Storage

When out of use, store the device as follows:

• dry,

• with a roof overhead,

• in an upright position where it is protected from

dust and direct sunlight,

• with a plastic cover to protect it from invasive dust,

if necessary.

• The storage temperature is the same as the range

given for the operating temperature in the chapter
Technical data.

• After being switched on, the device operates fully

automatically until either a pre-set timer or the
float indicating that the condensation tank is full
takes care that the device switches itself off.

• So that the built in sensor can correctly detect the

humidity, the fan continues to operate until the de-
vice is switched off.

• Avoid open doors and windows.

Positioning

When positioning the device, observe the minimum
distance from walls or other objects as described in
chapter Technical data.

• Set the device in a level and stable position.

• If possible, set the device in the middle of a room

and keep it away from sources of heat.

• When positioning the device in wet areas such as

laundries, bath rooms or the like, secure the de-
vice locally with an RCD (Residual Current protec-
tive Device) which complies with the appropriate
regulations.

• Ensure that extension cords are completely un-

rolled.

Transport

Operation

C

C

A

B

D

Содержание TTK 75 E

Страница 1: ...TTK 75 E OPERATING MANUAL DEHUMIDIFIER EN TRT BA TTK75E TC 002 EN...

Страница 2: ......

Страница 3: ...tronically pro cessing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily follow...

Страница 4: ...ase into the condensation tray and through the integrated drain nozzle into the con densation tank 3 below This is fitted with a float to measure the fill level The device has a control panel 1 for op...

Страница 5: ...idity 30 80 Volume of airflow max 192 m h Electric connection 230 V 50 Hz Power consumption max 355 W Fuse home 10 A Condensation tank 3 l Refrigerant R410a Amount of refrigerant 160 g Weight 12 3 kg...

Страница 6: ...se the device TTK 75 E only for drying and dehumid ifying room air while adhering to and following the technical data Intended use encapsulates drying and dehumidifying living rooms bedrooms bathrooms...

Страница 7: ...ight position where it is protected from dust and direct sunlight with a plastic cover to protect it from invasive dust if necessary The storage temperature is the same as the range given for the oper...

Страница 8: ...automatic defrost is active 10 Condensation tank full indicator light Flashes once the maximum fill level of the condensation tank is reached or when the condensation tank is not installed correctly...

Страница 9: ...right to CONTINUOUS Normal operation mode In normal operation mode the device stops the dehu midification once the desired room humidity has been reached When the humidity in the rooms increases the...

Страница 10: ...pter Operating elements 2 Do not touch the mains plug with wet or damp hands 3 Remove the mains plug from the mains socket 4 Empty the condensation tank and wipe it dry with a clean cloth Check for dr...

Страница 11: ...ta Check that the selected humidity is realistic The humidity in the room must be above the selected range Reduce the preselected relative humidity by turning the rotary switch 12 if necessary Check t...

Страница 12: ...ace air filter X check for damages X check attachment screws X X carry out a test run X Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 check air inlets and outlets for dirt and f...

Страница 13: ...ned must only be carried out by specialist companies for cooling and air conditioning or by TROTEC Visual check for dirt in the inside of the device 1 Remove the air filter see chapter Cleaning the ai...

Страница 14: ...fier TTK 75 E EN Cleaning the housing and condensation tank 1 Use a soft lint free cloth for cleaning 2 Dampen the cloth with clean water Do not use sprays solvents alcohol based or abrasive cleaners...

Страница 15: ...3 Cleaning the air inlets and the air filter Caution Ensure that the air filter is not worn or damaged Before reinserting the air filter ensure that it is dry Read the chapter Maintenance intervals an...

Страница 16: ...oard 36 Fixture 7 Plate 22 Lamp assembly 37 Cover 8 Evaporator assembly 23 Knob 38 Cover 9 Condenser assembly 24 Capacitor 1 F 450 for fan motor 14 39 Humidity switch 10 Y tube 25 Fix metal 40 Sensor...

Страница 17: ...ose of the refrigerant oil mixture appropri ately and according to the national regulations in accordance with the EC Low Voltage Directive 2006 95 EC Annex III Section B and the EC Directive 2004 108...

Страница 18: ......

Страница 19: ......

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: