background image

EN

7

dehumidifier TTK 71 E

Assembly and installation

Scope of delivery

1 x Device

1 x Air filter

1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical data.

A

B

C

C

D

Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.

Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.

Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).

Only put up the device in an upright, stable position on firm
ground.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

When positioning the device, keep a sufficient distance to
heat sources.

Make sure that no curtains or other objects interfere with
the air flow.

When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.

Содержание ttk 71 e

Страница 1: ...TRT BA TTK71E TC2013 05 007 EN TTK 71 E EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructio...

Страница 3: ...ion the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an ele...

Страница 4: ...ders all claims for liability and guarantee null and void Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas h...

Страница 5: ...Information about the device Description of the device The device uses the principle of condensation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the air filter...

Страница 6: ...After transporting the device observe the following Set up the device in an upright position after transport Leave the device to rest for 12 to 24 hours so the refrigerant can accumulate within the co...

Страница 7: ...ervice Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas ap...

Страница 8: ...mage to the device Make sure that the air filter is installed before switching the device on Opening the ventilation flaps 1 Prior to switching the device on open the ventilation flaps at the air outl...

Страница 9: ...s displayed when the timer is activated Indicates the number or hours set Is displayed automatic switch off enabled 17 TIMER button Starts programming for the timer function 18 MODE button Selection o...

Страница 10: ...be adjusted in increments of 1 h Note Do not leave the operating device unattended in a freely accessible room with an activated timer Automatic switch off The device is switched on 1 Press the TIMER...

Страница 11: ...The device does not start Check the power connection Check the power cable and mains plug for damage Check the on site fusing Check the filling level of the condensation tank and empty it if necessar...

Страница 12: ...ed Disconnect the device from the mains and let it cool down for approx 10 minutes before reconnecting it The device might carry out an automatic defrost During automatic defrost the device does not d...

Страница 13: ...or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and cl...

Страница 14: ...entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs a...

Страница 15: ...air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the device 2 Clean the filter using a...

Страница 16: ...ing or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the device cannot be switch...

Страница 17: ...ction side 1 2 MPa Pressure outlet side 2 5 MPa Max permissible pressure 2 5 MPa Mains supply 220 240 V 50 Hz Max power input 0 42 W Nominal current 1 8 A Refrigerant R290 Amount of refrigerant 55 g G...

Страница 18: ...18 EN dehumidifier TTK 71 E Circuit diagram...

Страница 19: ...Floater 1 20 Suction Tube 1 4 Back Cover Defence Net 1 21 Discharge Tube 1 5 Outlet Grids 1 22 Evaporator Inlet Tube 4 6 Back Cover 1 23 Condensor 1 7 Cover Right 1 24 Evaporator 1 8 Out Evaporator 1...

Страница 20: ...dministration For further return options provided by us please refer to our website https de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re...

Страница 21: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: