dehumidifier TTK 70 HEPA
Activities required after maintenance
If you want to continue using the device:
• Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter
Value
Model
TTK 70 HEPA
Max. dehumidification
performance
24 l / 24 h
Dehumidification performance
@ 30 °C and 80 % RH
20 l / 24 h
Air flow rate
140 m
3
/h
Operating range (temperature) 5 °C to 32 °C
Operating range (relative
humidity)
30 % to 80 % RH
Pressure suction side
1.2 MPa
Pressure outlet side
2.5 MPa
Max. permissible pressure
2.5 MPa
Mains connection
220–240 V / 50 Hz
Max. power consumption
420 W
Nominal current
1.91 A
Refrigerant
R290
Amount of refrigerant
60 g
GWP factor
3
CO
2
equivalent
0.00018 t
Water tank
6.5 l
Sound pressure level
48 dB (A)
Dimensions (length x width x
height)
225 x 340 x 565 mm
Minimum distance to walls and
other objects
A: top
B: rear
C: side
D: front
50 cm
50 cm
50 cm
50 cm
Weight
14.5 kg