Trotec TTK 171 ECO Скачать руководство пользователя страница 6

6

EN

dehumidifier TTK 171 ECO

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

Before

 transporting the device, observe the following:

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Do not use the power cable to drag the device.

Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).

To make the device easier to transport, it is fitted with
wheels.

Do not incline the device by more than 45°, for otherwise
the device could be damaged.

Only wheel the device on a level and smooth surface.

After

 transporting the device, observe the following:

Set up the device in an upright position after transport.

Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.

Storage

Before

 storing the device, observe the following:

Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).

Empty and clean the condensation tank prior to storage.

Drain any possibly remaining condensate.

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

in an upright position where it is protected from dust and
direct sunlight

with a cover to protect it from invasive dust, if necessary

Place no further devices or objects on top of the device to
prevent it from being damaged.

Assembly and installation

Scope of delivery

1 x Device

1 x Transport handle

2 x Foot

2 x Transport wheel

1 x Condensation drain hose

12 x Screw

4 x Nut

8 x Washer

1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Содержание TTK 171 ECO

Страница 1: ...TRT BA TTK171ECO TC2014 18 003 EN TTK 171 ECO EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...sing the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions...

Страница 3: ...uction side is kept free of dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the d...

Страница 4: ...ator until it is below the dew point Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime The dehumidified cooled air is slightly warmed at the condenser...

Страница 5: ...5 11 10 6 8 9 7 No Designation 1 Transport handle 2 Operating element 3 Recessed handle 4 Transport wheel 5 Feed through for condensation drain hose 6 Air outlet 7 Condensation tank 8 Venting slots 9...

Страница 6: ...ore switching the device back on Acting contrary might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device observe the foll...

Страница 7: ...s and the axle must be attached to the device To do so please proceed as follows The device is placed on its front side 1 Place a washer 12 on the axle 13 2 Place a wheel 4 in front of the washer 3 Pl...

Страница 8: ...ng the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create trippi...

Страница 9: ...the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on Inserting the con...

Страница 10: ...witch on timer function For enabling or disabling the automatic switch off timer function 21 On Off button For switching the device on or off No Designation Meaning 22 Timer LED Illuminated when the t...

Страница 11: ...automatic switch on upon expiry of a preset number of hours automatic switch off upon expiry of a preset number of hours The function can be set in all operating modes and also during stand by The nu...

Страница 12: ...switch on If the device is disconnected from the power supply all settings for automatic switch on are deleted Manually switching the device on disables the automatic switch on function If you select...

Страница 13: ...vice is running but there is no formation of condensate Check whether the condensation drain hose is positioned correctly Check the float in the condensation tank for dirt If necessary clean the conde...

Страница 14: ...de of the device is dirty have it cleaned by a specialist company for cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the...

Страница 15: ...t least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter f...

Страница 16: ...irt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and dra...

Страница 17: ...side of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in...

Страница 18: ...float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the devic...

Страница 19: ...ulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your...

Страница 20: ...inery Directive in the version 2006 42 EC Product model Product TTK 171 ECO Product type dehumidifier Year of manufacture as of 2018 Relevant EU directives Applied harmonised standards EN ISO 12100 20...

Страница 21: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: