EN
12
Operating manual – designer glass convector TCH 2000 E
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist electrical company or by Trotec.
The device is switched on, but the heating is not operating:
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
Check whether the overheating protection has tripped, see
chapter Safety.
•
The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
The air current is reduced:
•
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
Notice
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth. Wipe the housing dry
after cleaning.
Technical annex
Technical data
Parameter
Value
Model
TCH 2000 E
Heating capacity
1000 W – 2000 W
Setting range
15 °C to 50 °C
Mains connection
220 – 240V / 50/60 Hz
Power input
2000 W
Nominal current consumption
8.3 A
Cable length
1.6 m
Weight
9.5 kg
Dimensions
(length x width x height)
120 x 860 x 470 mm
Plug type
CEE 7/7
Minimum distance to walls and
other objects
A: top:
B: rear:
C: side:
D: front:
60 cm
30 cm
30 cm
30 cm