Description of the device
Air cleaners are used to filter the room air. On building sites and
renovation areas high concentrations of dust can arise, for
instance when using angle grinders or during blasting, chiselling
or demolition operations as well as when mixing dry mortar or tile
cement.
The air is conveyed through the air intake opening (10) via the
filters. The air filtered this way can stream back outside via the air
outlets (4) at the sides and on top.
Filter types (not included in the scope of delivery)
The following air filters are geared to the device and come with
the largest possible filter surface based on the geometric
dimensions. Consequently, a high air flow rate is achieved.
Note:
Please observe that only one prefilter (1, 2 or 3) can be imple-
mented in a device at a time. Operation without prefilter is not
advisable, for otherwise the fan could be damaged and the life-
time of the high-efficiency particulate air filter (4) is reduced.
Device depiction
Information about the device
No.
Designation
1
G4 Z line filter
2
Pleated filter F7
3
G3 spray paint filter
4
H13 high-efficiency particulate air filter (HEPA)
1
2
4
3
No.
Designation
5
Air outlet
6
Tension lock
7
Front cover
8
On/off switch
9
Power cable connection
10
Speed controller
11
Air intake opening
12
Transport handle
6
5
5
6
7
8
10
12
9
11