Operating Manual – Air Cleaner TAC 1500 / TAC 3000
6
• When putting up the device, position it in the room's centre
the air of which is to be cleaned. Alternatively, you can also
position the device near the source of air contamination.
• Prior to operation you have to ensure that the filters have
been installed in the device as desired.
• Also check, whether the pressure sensors are connected cor-
rectly. If the device, during operation, emits a warning of a fil-
ter being spent, the respective filter has to be replaced.
• Put the device up in a level, upright and stable position.
• Do not create tripping hazards when laying the power cable
or other electrical cables.
• Ensure that extension cords are completely unrolled.
Installation of the device in the room, the air of which is
to be purified
• The device works in recirculation mode, this means that the
contaminated air enters the air cleaner via the air inlet and is
blown out through the air outlet in purified state.
Fig. 8 Air purification in sealed off area via air circulation
Installation of the device outside of the room, the air of
which is to be purified
The device can be connected in either recirculation or ventilation
mode.
• In recirculation mode, the air to be cleaned is led via a hose
from the room into the air inlet of the device. The purified air
is fed through another hose from the air outlet and back into
the room.
• In ventilation mode, the air to be cleaned is led via a hose
from the room into the air inlet of the device. This creates a
slight negative pressure in the room. Clean, fresh air flows in
from outside.
Fig. 9 Installation variants for maintaining the pressure
When connecting pipes or hoses,
the following is to be observed:
• The used pipes and hoses must be designed for the available
static compression of the fans. They should preferably be laid
in a straight line and at full length. 7.6 m of air hose each can
be connected to both the TAC 1500's air inlet and outlet.
• To prevent an immediate neutralization of the air flows, air in-
let and air outlet should be positioned at a distance of at least
1 m from one another.
Control panel
Fig. 10 Control panel
Switch-on
• Switch the device on by actuating the mains switch (1). En-
sure that air inlet and outlet are not covered. The integrated
indicator light lights up.
Switch-off
• Switch the device off by actuating the mains switch (1). The
integrated indicator light goes off.
Operation
No.
Designation
1
mains switch
2
fan speed controller
3
filter indication pre-filter (coarse particulate air filter G4
& fine particulate air filter F7)
4
filter indication high-efficiency particulate air filter
(HEPA H13)
HE
PA
FILTER
FE
IN F
ILTER
1
2
3
4