Operating Manual – Air Cleaner TAC 1500 / TAC 3000

6

• When putting up the device, position it in the room's centre

the air of which is to be cleaned. Alternatively, you can also
position the device near the source of air contamination.

• Prior to operation you have to ensure that the filters have

been installed in the device as desired. 

• Also check, whether the pressure sensors are connected cor-

rectly. If the device, during operation, emits a warning of a fil-
ter being spent, the respective filter has to be replaced.

• Put the device up in a level, upright and stable position.

• Do not create tripping hazards when laying the power cable

or other electrical cables.

• Ensure that extension cords are completely unrolled.

Installation of the device in the room, the air of which is 
to be purified

• The device works in recirculation mode, this means that the

contaminated air enters the air cleaner via the air inlet and is
blown out through the air outlet in purified state.

Fig. 8  Air purification in sealed off area via air circulation

Installation of the device outside of the room, the air of 
which is to be purified

The device can be connected in either recirculation or ventilation
mode. 

• In recirculation mode, the air to be cleaned is led via a hose

from the room into the air inlet of the device. The purified air
is fed through another hose from the air outlet and back into
the room.

• In ventilation mode, the air to be cleaned is led via a hose

from the room into the air inlet of the device. This creates a
slight negative pressure in the room. Clean, fresh air flows in
from outside.

Fig. 9  Installation variants for maintaining the pressure

When connecting pipes or hoses,
the following is to be observed:

• The used pipes and hoses must be designed for the available

static compression of the fans. They should preferably be laid
in a straight line and at full length. 7.6 m of air hose each can
be connected to both the TAC 1500's air inlet and outlet.

• To prevent an immediate neutralization of the air flows, air in-

let and air outlet should be positioned at a distance of at least
1 m from one another.

Control panel

Fig. 10  Control panel

Switch-on

• Switch the device on by actuating the mains switch (1). En-

sure that air inlet and outlet are not covered. The integrated
indicator light lights up. 

Switch-off

• Switch the device off by actuating the mains switch (1). The

integrated indicator light goes off.

Operation

No.

Designation

1

mains switch

2

fan speed controller

3

filter indication pre-filter (coarse particulate air filter G4 
& fine particulate air filter F7)

4

filter indication high-efficiency particulate air filter 
(HEPA H13)

HE

PA 

FILTER

FE

IN F

ILTER

1

2

3

4

Содержание TAC 1500

Страница 1: ...OPERATING MANUAL AIR CLEANER TAC 1500 TAC 3000 EN TRT BA TAC1500_3000TC 004 EN...

Страница 2: ...ges to construction in the interests of constant improve ments to the product as well as changes to the shape and colour are reserved The scope of delivery may vary from product images This docu ment...

Страница 3: ...sing during the above mentioned operations A TAC air cleaner is fundamentally made up of the following com ponents housing adjustable fan for air transport filter boxes for the integration of filter t...

Страница 4: ...und Any unau thorised changes modifications or alterations of the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with ele...

Страница 5: ...es must be connected as indicated in the figure below Fig 3 Connection diagram of pressure sensor hoses in the cleanroom arrangement Standard arrangement Here the motor is positioned as the last eleme...

Страница 6: ...in the pre filter box Fig 6 b Bag filter arrangement wiring For proper monitoring of the filter technology the pressure sensor hoses must be connected as indicated in the figure below Fig 7 Connectio...

Страница 7: ...led via a hose from the room into the air inlet of the device The purified air is fed through another hose from the air outlet and back into the room In ventilation mode the air to be cleaned is led v...

Страница 8: ...nel Fig 12 Side view 2 of TAC 3000 without side panel Fig 13 Side view 2 of TAC 1500 without side panel Shutdown 1 Switch off the device 2 Remove the mains plug from the mains socket 3 Clean the devic...

Страница 9: ...e mains plug with wet or damp hands Before any work detach the mains plug Maintenance tasks which require the housing to be opened must only be carried out by a specialist com pany or by TROTEC Filter...

Страница 10: ...n the pre filter box and the fan housing 8 Mount the side panels Make sure that the side panels are grounded Fig 16 Removing the filter When the device warns of a spent pre filter and or HEPA filter s...

Страница 11: ...horized changes of the facto ry supplied device version this declaration loses its legal validity Device version Air Cleaner Series TAC Year of manufacture as of April 2014 Applicable regulations Appl...

Страница 12: ...200 250 Sound level distance 1 m 61 dBA 65 dBA Dimensions L x W x H 705 mm x 362 mm x 377 mm 833 mm x 460 mm x 519 mm Weight full 22 kg 36 kg Mobility portable wheeled stackable yes yes yes yes yes ye...

Страница 13: ...und Abluftschlauch mit Filterkombination G4 H13 Zulassung f r Staubklasse H und Abluftschlauch empfohlene Luftmenge f r Staubklasse H 0 0 200 400 600 800 1 000 1 200 1 400 1 600 1 800 2 000 2 200 2 40...

Страница 14: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 0 49 2452 962 200 info trotec com www trotec com...

Отзывы: